C-Tec 12V 2A EN54-4 Switch Mode PSU
£90.19 (inc VAT: £108.23)
Summary
The C-TEC BF560-12 is a powerful 12V 2A switch mode/digital hybrid power supply unit specifically designed for fire alarm and security applications. Certified to EN54-4/A2 by both LPCB and VdS, this PSU offers exceptional reliability and compliance for critical life safety systems.
This versatile power supply can be customised to suit exact project requirements, making it ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities. The unit combines advanced monitoring capabilities with robust safety features, including comprehensive fault detection and battery management systems.
With electronic functions complying with EN50131-6 grades 1-4 for security applications, the BF560-12 provides a cost-effective solution for ensuring fire alarm systems meet strict compliance requirements when connected to remote monitoring centres.
Features
- Certified to EN54-4/A2 by LPCB & VdS with AFNOR pending
- Customisable switch mode/digital hybrid PSU design
- Plastic cover on PSU PCB guards against touching live parts
- Single-pole voltfree changeover relay for any fault condition
- Multiple indicators for supply present, general fault, fault type and auxiliary equipment fault
- Two selectable battery charge currents
- Optimisable battery fault impedance limits to extend battery life
- Mains fail simulation mode
- Improved on-board temperature sensor with optional remote sensor
- Ideal for connecting to 12V security STUs for BS5839-1 compliant remote monitoring
- Electronic functions comply with EN50131-6 grades 1-4 for security applications
- BF560-12/E encased PCB version also available
- Bi-directional data port for status extraction
- Battery resistance monitoring compliant with EN54-4/A2
- Optional STU mounting plate available (BF360SP)
FAQ
What certifications does the BF560-12 have?
The BF560-12 is certified to EN54-4/A2 by both LPCB and VdS, with AFNOR certification pending. It also complies with EN50131-6 grades 1-4 for security applications.
Can the PSU be customised for specific requirements?
Yes, the BF560-12 can be customised using a BF423 configurator and PC. Configurable parameters include float voltage temperature compensation, battery charge rate, battery impedance and input/output settings. However, any customisation is outside the scope of EN54-4 and must be tested by the responsible person.
What battery sizes are supported?
The PSU supports battery capacities from 2Ah up to 12Ah, with maximum battery sizes of 1 x 12V 3.2Ah VRLA (with STU plate fitted) or 1 x 12V 7Ah VRLA (without STU plate fitted).
How does the PSU help with BS5839-1 compliance?
The BF560-12 solves compliance issues when connecting fire alarm systems to remote monitoring centres via 12V security STUs. It provides the EN54-4 features required by BS5839-1, including battery impedance monitoring, temperature compensated charging and dedicated mains supply.
What do the LED status indicators mean?
The PSU status LED shows different flash patterns: 1 flash = Mains Failure, 2 flashes = Battery Voltage Low, 3 flashes = Battery Voltage Critical, 4 flashes = Charger Failure, 5 flashes = Charger OK, 6 flashes = No Batteries Fitted, 7 flashes = Battery Resistance Fault, 8 flashes = Output Over Voltage.
Is an encased version available?
Yes, the BF560-12/E encased PCB version is also available for applications requiring additional protection.
Specifications
- Approvals Certifications: Certified to EN54-4/A2 by the LPCB & VdS
- Application Operation: Boxed mains to regulated DC switch-mode/digital hybrid power supply providing 2A @ 12V DC with single pole volt-free changeover relay
- Mains Supply: 230V 50/60Hz
- Mains Rated Current: 300mA r.m.s.
- Total Output Current Limited To: 2A (Max. output current)
- Output: I max.a: 1.8A or 1.3A selectable (1.8A not approved to EN54-4/A2), I.max.b: 2A charging turned off via CONN6
- Battery Charge Capacity: 2Ah up to 12Ah (battery charged to 80% capacity in 24 hrs)
- Max Battery Size And Type: 1 x 12V 3.2Ah VRLA (with STU plate fitted); 1 x 12V 7Ah VRLA (without STU plate fitted)
- Indicators: 3 external – Supply Present (green); General Fault (amber); Auxiliary Fault (amber) and 2 internal – Hazardous Voltages Present (red) and PSU Status (amber)
- Connections: Mains Input (CONN1); Supply Output (CONN5); Battery Input (CONN5); Fault Relay (CONN4); BF423 Configurator Connector (PL2); Remote Thermistor Connector (PL3); Battery Charger Inhibit & Input/Output
- Expansion Connections: Remote thermistor can be connected via PL3 terminals
- Product Dimensions: 380mm W x 235mm H x 96mm D
- Construction Finish: PVC lid and base; RAL7035 textured
- IP Rating: IP30 (to EN 60529). Designed for indoor use only
- Weight: 1.55kg (without batteries)
- Operating Conditions Temperature: -5ºC to +40ºC. Max relative humidity: 95%
- Notes: Parameters configurable via BF423 configurator: Float voltage temp. compensation; Battery charge rate (mA); Battery impedance; Configurable Input/Output settings
Downloads
- Datasheet (Adobe PDF)
Additional information
| Output | 2A |
|---|