Lexicomm Type C Vandal Proof Outstation
£518.75 (inc VAT: £622.50)
Summary
The Lexicomm ViLX-VRC is a vandal resistant Type C outstation that combines a Type A fire telephone and a Type B disabled refuge point into a single robust unit. With a secure key lock on the front, the fire telephone function is only accessible to authorized personnel who require access, while the key lock also prevents any of the internal electronics from being accessible and potentially damaged by vandals. The sturdy call button on the front allows the outstation to be used for disabled refuge purposes by all building users.
All Lexicomm Emergency Voice Communications Systems (EVCS) are designed to comply fully with the requirements of BS 5839-9:2021 for use as a fire telephone system (FT), disabled refuge system (DRS), or as a combined system when both fire telephones and disabled refuge call points are required. The ViLX-VRC represents the optimal solution for environments where vandalism is a concern but full accessibility for emergency refuge must be maintained.
The outstation features a ruggedized handset with high volume ringer for clear communication in noisy environments, housed within a texture painted steel enclosure finished in RAL 7035. Installation is simplified through the use of a single 2 core enhanced fire resistant cable connected to a Lexicomm or UnicornVoice system. The outstation is fully monitored for short and open circuit faults which display on the master panel, providing confidence that the system is wired correctly both during and after installation.
Features
- Vandal resistant Type C outstation design
- Combines Type A fire telephone and Type B disabled refuge point in single unit
- Ruggedized handset for durability in demanding environments
- High volume ringer for clear audible alerts
- Key lock secured handset restricts access to authorized users only
- Key lock protects internal electronics from vandalism
- Protected Type B outstation for disabled refuge use
- Sturdy call button with visual indication for refuge point activation
- Fully compliant to BS 5839-9:2021 standards
- Single 2 core fire cable connection for simplified wiring
- Compatible with Lexicomm and UnicornVoice systems
- Full fault monitoring for short and open circuit conditions
- Fault status displayed on master panel
- Texture painted steel construction for durability
- RAL 7035 painted finish
- Mounted at 1300-1400mm height for BS 5839-9:2021 compliance
- Suitable space allocation for wheelchair access at refuge point
- Enhanced fire resistant cable up to 500m from panel
- Network wiring in ring configuration supported
- Compatible with LexiCommPro panels supporting up to 8 lines
- EMC compliant to EN 55035:2017+A11:2020 and EN 55032:2015+A1:2020
- LVD compliant to EN IEC62368-1:2020+A11:2020
- Compliant to BS 9999:2017 and BS 8300-2:2018 standards
FAQs
What is a Type C outstation?
A Type C outstation as defined in BS 5839-9:2021 is a combined unit that incorporates both a Type A fire telephone (for use by building management, fire wardens, and firefighters) and a Type B disabled refuge point (for use by building occupants requiring assistance). The ViLX-VRC combines both functions in a single vandal-resistant enclosure.
How does the vandal resistance work?
The ViLX-VRC features a key lock on the front that secures the fire telephone handset, making it accessible only to authorized personnel with the key. This key lock also prevents access to the internal electronics, protecting them from potential vandalism. The disabled refuge call button remains accessible to all users without requiring a key.
Who can use the different functions of the ViLX-VRC?
The fire telephone function (Type A) requires a key and is restricted to authorized personnel such as building management, fire wardens, and firefighters. The disabled refuge point function (Type B) is accessed via the sturdy call button on the front, which is available to all building users, particularly those requiring assistance during an emergency.
What height should the ViLX-VRC be mounted at?
The ViLX-VRC should be mounted at a height of 1300 to 1400mm from the floor to the centre line of the outstation to comply with BS 5839-9:2021 requirements. As the outstation also functions as a refuge point, suitable space must be allowed so the system can be accessed by a person in a parked wheelchair.
What cabling is required for the ViLX-VRC?
The ViLX-VRC requires only a single 2 core enhanced fire resistant cable (1mm or 1.5mm CSA) connected to a Lexicomm or UnicornVoice system. The cable can run up to 500m from the compatible panel, and multiple outstations can be wired in a ring network configuration.
Does the ViLX-VRC provide fault monitoring?
Yes, the ViLX-VRC is fully monitored for short circuit and open circuit faults. These fault conditions are displayed on the master panel, providing confidence that the outstation is wired correctly both during installation and throughout its operational life.
What standards does the ViLX-VRC comply with?
The ViLX-VRC is fully compliant with BS 5839-9:2021 (fire telephone and disabled refuge systems), BS 9999:2017 (fire safety code of practice), and BS 8300-2:2018 (accessibility standards). It also meets EMC standards EN 55035:2017+A11:2020 and EN 55032:2015+A1:2020, plus LVD standard EN IEC62368-1:2020+A11:2020.
What is the construction of the ViLX-VRC?
The ViLX-VRC is constructed from texture painted steel with a RAL 7035 painted finish, providing robust protection against vandalism. It measures 300mm in height, 150mm in width, and 130mm in depth to the handle front, with a weight of 2.8kg.
Can the ViLX-VRC be used in environments prone to vandalism?
Yes, the ViLX-VRC is specifically designed for environments where vandalism is a concern. The key-locked handset and protected electronics ensure the fire telephone function remains secure, while the exposed call button still allows the disabled refuge function to be used by all building occupants.
How many ViLX-VRC units can be connected to a single panel?
LexiCommPro panels can accommodate up to 8 lines, with multiple ViLX-VRC outstations able to be connected on each line. The exact number depends on the system configuration and cable runs.
Specifications
- Product Code: ViLX-VRC
- Product Type: Vandal Resistant Type C Outstation
- Outstation Classification: Type A Fire Telephone + Type B Disabled Refuge Point
- Height: 300mm
- Width: 150mm
- Depth: 130mm to handle front
- Weight: 2.8kg
- Material: Texture painted Steel
- Finish: Painted RAL 7035
- Handset Type: Ruggedized
- Ringer: High volume
- Access Control: Key lock secured handset
- Call Button: Sturdy call button with indication
- Mounting Height: 1300 to 1400mm from floor to centre line
- Wheelchair Access: Suitable space required for parked wheelchair
- Wiring Requirement: Single 2 core fire cable
- Compatible Systems: Lexicomm and UnicornVoice systems
- Fault Monitoring: Full monitoring for short and open circuit faults
- Fault Display: Displayed on master panel
- Recommended Cable Type: Enhanced Fire Resistant
- Recommended Cable Cores: 1mm or 1.5mm
- Maximum Distance From Panel: 500m
- Network Configuration: Ring wiring supported with 2 x 2 core 1.5mm CSA Enhanced Fire Cable
- Panel Capacity: Each LexiCommPro panel accommodates up to 8 lines
- EMC Compliance: EN 55035:2017+A11:2020, EN 55032:2015+A1:2020
- LVD Compliance: EN IEC62368-1:2020+A11:2020
- Product Family Standards: BS 5839-9:2021, BS 9999:2017, BS 8300-2:2018
- Document Reference: DViLXVRC0001-02
- Manufacturer: Vox Ignis
- Company Registration: 8892407