Baldwin Boxall OCBARG OmniCALL Type B Advanced Refuge Outstation | Two-Way Speech, BS 5839-9
£487.74 (inc VAT: £585.29)
Key features
- Loop or radial wiring options
- Induction loop for hearing aid users
- Assistance alarms shown separately at master station
Downloads
Summary
The Baldwin Boxall OCBARG is a Type B advanced refuge outstation for the OmniCALL emergency voice communication (EVC) system, designed to give disabled refuge points reliable two-way speech without adding to your first-fix power budget.
View full overview Show less
For installers, that means fewer cable runs to plan and less coordination with the mains supply on site, while still delivering a refuge point that meets BS5839-9:2021 and BS8893:2024. It’s a straightforward way to add compliant disabled refuge communication to a job without complicating the containment design.
The OCBARG draws its power from the OmniCALL loop or radial circuit itself, so no local power supply is needed at the outstation, including when the emergency assistance alarm is triggered. It can be wired on the same loop as other OmniCALL outstations or run as a radial from the control panel, giving you flexibility to fit the cable route already on the drawing.
Features
- Loop or radial wiring - fit into whichever OmniCALL topology suits the building’s containment route
- No local power required - powered from the loop or radial, cutting cabling and commissioning time
- Induction loop - supports hearing aid users at the refuge point
- Braille and luminescent labelling - helps meet accessibility expectations for disabled refuge calls
- Two-way, hands-free half duplex speech - lets refuge users communicate clearly with the master station without holding a handset
- Separate assistance alarm indication - master station distinguishes refuge alarms from other outstation activity
- Reset via outstation button push - simplifies day-to-day testing and reset on site
- Optional fire detection system link - helps prevent hoax disabled refuge calls
- Loudspeaker isolation output - works with the OCSPRISOL unit to isolate a local loudspeaker when required
- Surface or flush mounting - fit as standard or flush via the OCBARG-BZ bezel to suit the finish specified
FAQ
No local power supply is needed, as the OCBARG is powered directly from the OmniCALL loop or radial circuit. Battery backup and standby duration are provided at the master station/panel level rather than at the outstation itself, so check the OmniCALL master station documentation for the specific standby time achieved on your system. Yes. It’s surface mounted as standard but can be flush mounted using the OCBARG-BZ bezel. Check the bezel cutout dimensions against your wall preparation before first fix. Yes, the OCBARG can be wired on the same loop as other OmniCALL outstations or connected via a radial from the control panel. An optional link between the OmniCALL console and the fire detection system can also be configured to help prevent hoax disabled refuge calls; this forms part of the wider system design, so refer to the manufacturer’s installation documentation for wiring details. It’s designed to meet BS 5839-9:2021 and BS 8893:2024, which cover emergency voice communication systems including disabled refuge points. Wider requirements such as BS 9999 and Building Regulations relate to the overall fire strategy and evacuation provisions for the building, so these should be confirmed with the building’s fire risk assessment or building control rather than from this outstation’s datasheet alone. The datasheet doesn’t specify a maximum cable run length or a mandated cable type for the loop or radial wiring. Cable specification and permitted run lengths depend on the overall OmniCALL system design, so confirm these details with Baldwin Boxall’s installation documentation or technical support before finalising the containment design. Yes, the OCBARG includes a built-in induction loop for hearing aid users at the refuge point, in line with the accessibility requirements for disabled refuge outstations.Does the OCBARG need its own local power supply or battery backup?
Can the OCBARG be flush mounted?
Can it be wired on the same loop as other outstations, and does it need to link to the fire alarm panel?
Which standards does the OCBARG help you comply with?
What cable type and maximum run length should be used with the OCBARG?
Does the OCBARG support hearing aid users?
Specifications
| Product Code | OCBARG |
|---|---|
| Power Supply | 15-36V |
| Power Consumption | 70mA @ 24V |
| Humidity Range | 0-90% non-condensing |
| Temperature Range | -5°C to +40°C |
| Indicators | Status |
| Finish | RAL 6024 |
| Dimensions (W x H x D) | 134 x 134 x 64 mm |
| Bezel Dimensions (W x H) | 154 x 154 mm |
| Bezel Cutout (W x H) | 136 x 136 mm |
| Knockouts/Cable Entry Points | 20 mm and 25 mm |
Downloads
- Datasheet (Adobe PDF)
Additional information
| Device Type | |
|---|---|
| Colour | |
| Enclosure |