C-Tec EP203 Automatic Extinguisher Panel
£260.55 (inc VAT: £312.66)
Summary
The EP203 Automatic Extinguisher Panel is a high-quality, durable, and reliable solution certified by the LPCB to EN 12094-1 and EN54-2/4 standards. This panel is specifically designed for environments that house expensive, dangerous, or irreplaceable equipment. It features an intuitive 128 x 64 pixel display that provides clear and concise feedback to users, installers, and commissioning engineers.
With six monitored inputs, including hold and abort functions, a time-stamped log, adjustable flood times, and volt-free changeover relays for various functions, the EP203 is engineered for ease of installation and operation. The panel’s electronics are mounted on a detachable metal bridge plate, and a wide range of ancillary options are available to enhance its functionality.
Features
- Functions as a standard 3 zone fire panel with additional circuitry for gas release
- Manual release button and two keyswitches
- 3 conventional sounder circuits
- Powerful 3A EN54-4 switch mode PSU
- Wide range of monitored inputs and auxiliary outputs
- RS485 connections for remote status units
- Optional relay expansion boards
- System line terminator included
Specifications
- Approvals/Certifications : Certified to EN12094-1 and EN54-2 & 4 by the LPCB
- Mains Supply : 230V 50/60Hz
- Mains Rated Current : 810mA max
- Internal Power Supply : 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault)
- Total Output Current : Limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA)
- Quiescent Current : 40mA (on mains fail). Zone quiescent 2mA max
- Max Battery Size And Type : 2 x 12V 7Ah VRLA connected in series
- No. Of Detector Zone Circuits : 3 @ 19-28Vdc (Max. length per circuit is 250m)
- Max. Devices Per Detector Zone : 20 detectors (or 32 detectors/manual call points combined)
- No. Of Conventional Sounder Circuits : 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m
- EOL Resistor Value : 6800Ω 5% Tol. 0/25W (blue, grey, red, gold)
- Max. Sounder Output Current : 3 x 200mA
- Auxiliary Relays : Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays
- Other Outputs : Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to be active for 1-300 seconds and to flood for 60-1800 seconds
- Auxiliary Inputs : Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2KΩ normal; 1.8K-200Ω active; 150-0Ω short circuit. EOL value: 6K8 +/-5%, 0.25W
- Indicators : Multiple indicators are provided – refer to the EP203 instructions for details
- Expansion Connections : Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Economy status units (2 wire power + 2 wire mode select)
- Product Dimensions (mm) : 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid)
- Construction & Finish : Metal back box; metal chassis’ plastic lid
- IP Rating : IP30
- Weight : 4.2kg (without batteries)
- Operating Conditions/Temperature : -5ºC to +40ºC. Max relative humidity: 95%
Downloads
- Datasheet (Adobe PDF)
Additional information
| Device Type | |
|---|---|
| Networkable |