C-Tec Stainless Steel Emergency Assistance Alarm Kit
£178.93 (inc VAT: £214.72)
Summary
The C-TEC NC951/SS Stainless Steel Emergency Assistance Alarm Kit is a premium single zone emergency assistance system designed for high-profile disabled persons toilet applications. This attractively designed kit combines functionality with durability, featuring a brushed stainless steel finish that provides both aesthetic appeal and enhanced resistance to wear and vandalism.
The system operates through a simple pull cord mechanism, allowing a distressed person to quickly raise an alarm in emergency situations. When activated, the ceiling pull triggers both visual and audible alerts outside the WC facility and on the system’s Call Controller, ensuring immediate notification to assistance personnel.
This comprehensive kit includes all essential components: an NC941/SS 12V Stainless Steel Call Controller, NC806CS/SS Stainless Steel Overdoor Light with Sounder, NC809DB/SS Stainless Steel Reset Point, and an NC807C Plastic Ceiling Pull. The system can be easily installed using standard 4 core stranded security cable, making it suitable for various installation environments whilst maintaining professional appearance and reliability.
Features
- Brushed stainless steel construction for durability and vandal resistance
- Single zone emergency assistance alarm system
- Pull cord activation with ceiling-mounted trigger
- Visual and audible alarm indication both locally and at controller
- Complete kit including call controller, overdoor light with sounder, reset point and ceiling pull
- Standard 4 core cable wiring compatibility
- Expandable to accommodate up to 3 ceiling pulls via daisy-chain connection
- Red reassurance LEDs and alarm indicators
- Reset button functionality with optional disable feature
- Mains powered with 230V supply and internal 13-13.8V DC conversion
- IP41 rating for wall-mounted devices and IP21 for ceiling pull
- Wide operating temperature range from -5°C to +40°C
FAQ
Is this system suitable for all disabled toilet applications?
The NC951/SS is suitable for many high-profile disabled persons toilet alarm applications. However, if a fully BS8300 compliant accessible toilet alarm system is required, C-TEC recommends using their NC951 standard plastic kit instead.
Can I add multiple call points to the system?
Yes, for applications requiring more than one point of call (such as at both the WC and wash basin), up to 3 ceiling pulls can be daisy-chained together using the expansion connections.
What happens if there’s a mains power failure?
A remote battery back-up kit (part no. NC941B) can be connected to the NC941/SS to ensure the system remains operational for a limited time in the event of mains failure.
Does the system have call acknowledgement functionality?
No, this system does not include call acknowledgement functionality. If this feature is required, consider using C-TEC’s NC951 Accessible Toilet Alarm instead.
What type of cable is required for installation?
The system can be wired using standard 4 core stranded security cable, making installation straightforward with commonly available materials.
Specifications
- Mains Supply : 230V 50/60Hz (36mA max. current), 50Hz frequency
- Internal Power Supply : 13-13.8V d.c.
- Total Output Current Limited To : 250mA
- Quiescent Current : See individual device listings for NC941/SS, NC807C, NC806CS/SS and NC809DB/SS
- Max Battery Size And Type : A remote battery back-up kit (part no. NC941B) can be connected to the NC941/SS to ensure it remains operational for a limited amount of time in the event of Mains failure
- Alarm Current : TBC
- Auxiliary Relays : N/A
- Indicators : NC807C & NC809DB/SS have red Reassurance LEDs; NC806CS/SS has twin red Alarm LEDs. NC941/SS has a red Alarm and green Supply Present LED
- Controls : NC941/SS has a Reset button which can be optionally disabled; NC807C has a pull cord with two bangles to generate a call; NC809DB/SS has a Reset button
- Expansion Connections : For applications requiring more than one point of call (e.g. at the WC and the wash basin), up to 3 ceiling pulls can be daisychained together
- Call Acknowledgement Functionality : No. If this feature is required consider using our NC951 Accessible Toilet Alarm instead
- Onboard Sounder : Yes (on NC806CS and NC941/SS)
- Onboard Infrared Receiver : No
- Product Dimensions (mm) : 156 W x 94 H x 37 D (NC941/SS); 87 W x 87 H x 80 D (NC806CS/SS); 87 W x 87 H x 24 D (NC809DB/SS). Ceiling pull measures 93mm diameter x 27 D
- Packaging Dimensions (mm) : 285 W x 201 H x 55 D mm (size of NC951/SS kit box containing all items)
- Construction & Finish : Brushed stainless steel call controller, reset point and overdoor light; Plastic ceiling pull
- IP Rating : IP41 (all wall mounting devices); IP21 (ceiling pull)
- Weight : 995kg
- Operating Conditions/Temperature : -5ºC to +40ºC. Max. relative humidity 95% non-condensing
- Notes : For multi-zone stainless steel call systems consider using one or more of our NC944/SS call controllers and an NC930/SS 12V power supply