Shopping Basket

0 Items

Subtotal £0.00

Lexicomm AssistCall Weatherproof Cancel Plate

£100.00 (inc VAT: £120.00)

Low Stock

SKU: ViAC-CNP-66 Category: Brand:

Summary

The Vox Ignis ViAC-CNP-66 is a weatherproof cancel button designed specifically for use in wet environments such as shower rooms, en-suite bathrooms, and wet changing areas where a standard cancel button may be unsuitable. This IP66-rated device provides reliable alarm cancellation functionality while withstanding exposure to dust particles and water jets, making it the ideal choice for demanding healthcare and assisted living applications.

Finished in brushed stainless steel with a robust polycarbonate back box, the ViAC-CNP-66 combines durability with an attractive appearance suitable for modern healthcare facilities. The unit features a blue visual indicator that flashes when an alarm is activated and displays steady illumination when the alarm has been acknowledged, providing clear feedback to both users and care staff. The momentary sprung switch mechanism ensures reliable operation, cancelling the alarm when pressed.

Fully compatible with the Lexicomm EVC range of equipment, Lexicomm LX228 and Network panels, and the standalone AssistCall range including 4 Zone and 1 Zone controllers and the ViAC-RTK Remote kit, this cancel button integrates seamlessly into existing nurse call and disabled toilet alarm systems. The unit should be mounted between 800mm and 1000mm from the floor in accordance with BS 8300-2:2018 standards, with a lower call button positioned at 100mm from the floor. The flexible design offers five 20mm cable entries at top, bottom, and side positions, plus rear entry via cut-out, ensuring straightforward installation with standard two-core cabling in any wiring order.

Features

  • IP66 weatherproof enclosure tested against dust particles and water jets
  • Ideal for showers, wet areas, en-suite bathrooms and wet changing rooms
  • Brushed stainless steel fascia for durability and aesthetic appeal
  • Tough polycarbonate back box construction
  • Blue visual indicator for alarm status feedback
  • Flashing blue indicator when alarm activated, steady when acknowledged
  • Momentary sprung switch for alarm cancellation
  • BS 8300-2:2018 compliant “Acknowledge” feature
  • Flush or surface mounting installation options
  • Compatible with Lexicomm LX228 and Lexicomm Network range panels
  • Compatible with AssistCall standalone 4 Zone and 1 Zone controllers
  • Compatible with ViAC-RTK Remote kit
  • Can replace standard ViAC-CNP cancel plates (visual indication only)
  • Five 20mm cable entry positions: top, bottom, side and rear via cut-out
  • Simple two-core cable wiring with flexible wiring order
  • Recommended mounting height: 800mm to 1000mm from floor
  • Compact dimensions: 100mm x 100mm x 60mm
  • Lightweight at 250g for easy installation
  • Drain hole provision for appropriate installations
  • Four Allen screw cover fixing for secure installation
  • Slotted fixing holes for rotation adjustment during installation
  • Supplied bungs for sealing fixing screw positions
  • Gasket seal included for weatherproof protection
  • EOL resistor fitting capability for last device in circuit
  • Designed and manufactured in the UK
  • EMC compliant: EN 55035:2017+A11:2020, EN 55032:2015+A1:2020
  • LVD compliant: EN IEC62368-1:2020+A11:2020
  • Product family standards: BS 5839-9:2021, BS 8300-2:2018
  • WEEE compliant product

FAQs

What is the IP66 rating and what does it mean for this product?

IP66 is an Ingress Protection rating that indicates the device is completely dust-tight (6) and protected against powerful water jets from any direction (6). This means the ViAC-CNP-66 has been tested against dust particles and water jets when installed appropriately in accordance with the installation instructions and with all seals correctly positioned. This makes it ideal for wet environments such as showers, bathrooms, and changing areas. However, it’s important to note that this product must not be immersed in water – it is protected against water jets, not full submersion.

Can the ViAC-CNP-66 be used to replace a standard cancel plate?

Yes, the ViAC-CNP-66 can be used to replace a standard ViAC-CNP cancel plate. However, it’s important to note that this weatherproof version only has visual indication (the blue LED) – it does not include an audible sounder. This makes it suitable for wet areas where a standard cancel may be unsuitable, but you should ensure that visual indication alone meets your application requirements.

How many cancel buttons are typically required in an installation?

Generally, one cancel button is used per room or area. However, in some cases, two units may be required. If you need to install multiple cancel buttons in the same space, it’s recommended to contact the Vox Ignis technical department for guidance on the correct configuration for your specific installation.

What systems is the ViAC-CNP-66 compatible with?

The ViAC-CNP-66 is fully compatible with several Vox Ignis and Lexicomm systems including: the Lexicomm EVC range of equipment, Lexicomm LX228 panels, Lexicomm Network range of panels, AssistCall standalone 4 Zone controllers, AssistCall 1 Zone controllers, and the ViAC-RTK Remote kit. This wide compatibility makes it a versatile solution for both new installations and upgrades to existing systems.

What is the correct mounting height for the cancel button?

The ViAC-CNP-66 should be mounted between 800mm and 1000mm from the floor in accordance with BS 8300-2:2018 standards. Additionally, a lower call button should be mounted at 100mm from the floor to ensure accessibility for users who may have fallen or are in different positions. This dual-height arrangement ensures the alarm system is accessible in various emergency situations.

What cable entries are available and where should drain holes be positioned?

The unit provides five 20mm cable entry positions: top, bottom, side, and rear (via cut-out). For side, top, or rear entry installations, the lowermost drain hole must be drilled out using a 5mm drill – only one drain hole position should be drilled. For bottom entry, a drain hole must NOT be drilled in the rear box, but must be drilled at the lowermost point of the conduit run. Opening the drain hole will compromise the IP66 rating, so particular care should be taken to ensure no water is directed at the drain hole once installed.

What wiring is required for installation?

For simplicity, all wiring uses standard two-core cable. The wiring order of devices is not fixed and can be connected in any order, giving total flexibility during installation. The cable should be connected to the Line + and 0 terminals. There are two sets of 2-part removable terminals which are not marked as in or out – it doesn’t matter which is used for incoming or outgoing connections, however polarity is important and must be observed. Recommended cables are 2 core 1mm PVC or fire rated cable up to 500m, or Cat5/6 (1 pair 0.22mm) up to 50m from the panel/controller.

How should the stainless steel surface be maintained?

Over time, environmental conditions and weathering may affect the stainless steel finish of the product, particularly in coastal regions where some discolouration may occur. It is recommended that the surface is cleaned with a soft cloth soaked in neutral oil, such as WD-40. This cleaning process should be repeated up to four times per year to maintain the appearance and protective qualities of the stainless steel finish.

What happens when an alarm is activated and acknowledged?

When an alarm is activated, the blue indicator on the cancel button flashes to provide visual feedback. When a care staff member or responder acknowledges the alarm, the indicator changes to steady (non-flashing) illumination. The button itself is a momentary sprung switch, which means when pressed, it cancels the alarm. This provides clear visual communication of the alarm status to both users and staff.

What is the EOL resistor and when should it be fitted?

EOL stands for End Of Line resistor. If the ViAC-CNP-66 is the last device in the circuit, the EOL resistor should be fitted to the unused terminal set. This is applicable for monitored line circuits and allows the control panel to detect faults in the wiring such as open or short circuits. Note that 1 Zone controllers do not have monitored line circuits and therefore do not require an EOL resistor.

Specifications

General

  • Model Number: ViAC-CNP-66
  • Product Type: IP66 weatherproof cancel button
  • Manufacturer: Vox Ignis Limited (UK designed and manufactured)
  • Product Family: AssistCall range
  • Switch Type: Momentary sprung switch (non-latching)

Physical

  • Height: 100mm
  • Width: 100mm
  • Depth: 60mm
  • Weight: 250g
  • Material: Stainless Steel/Tough polycarbonate
  • Finish: Brushed stainless steel
  • Mounting Options: Flush or surface mounting
  • Cable Entries: 5 x 20mm (top, bottom, side, and rear via cut-out)
  • Fixing Method: Four Allen screws

Visual Indication

  • Indicator Type: Blue LED
  • Alarm Activated: Flashing blue
  • Alarm Acknowledged: Steady blue
  • Audible Sounder: None (visual indication only)

Environmental

  • Ip Rating: IP66 (dust tight and protected against water jets)
  • Typical Applications: Shower rooms, en-suite bathrooms, wet changing areas
  • Immersion Protection: Must not be immersed in water
  • Maintenance: Clean with neutral oil up to 4 times per year

Installation

  • Mounting Height: 800mm to 1000mm from floor (per BS 8300-2:2018)
  • Lower Call Button Height: 100mm from floor
  • Mounting Surface: Clean, rigid vertical surface suitable for screw fixings
  • Fixing Screws: No 8 screws in four or at least two diagonal positions
  • Drain Hole: 5mm (when required, compromises IP rating)

Wiring

  • Cable Type: Standard two-core cable
  • Wiring Order: Flexible (not fixed, can be wired in any order)
  • Terminal Type: 2 sets of 2-Part/removable terminals (Line + and 0)
  • Polarity: Important (must be observed)
  • Eol Resistor: Fit to unused terminal if last device in circuit (where applicable)

Recommended Cables

  • Pvc Or Fire Rated: 2 core 1mm, distance from panel/controller: 500m
  • Cat5/6: 1 x pair 0.22mm, distance from panel/controller: 50m
  • Fire Rated Note: *If connected to a Refuge Point

Compatibility

  • Lexicomm Systems: LX228, Lexicomm Network range, EVC range
  • Assistcall Systems: Standalone 4 Zone controllers, 1 Zone controllers
  • Remote Kits: ViAC-RTK Remote kit
  • Replacement Capability: Can replace ViAC-CNP standard cancel plate (visual indication only)

Standards Compliance

  • Emc: EMC EN 55035:2017+A11:2020, EN 55032:2015+A1:2020
  • Lvd: EN IEC62368-1:2020+A11:2020
  • Product Family: BS 5839-9:2021, BS 8300-2:2018
  • Weee: Compliant

Part Numbers

  • Cancel Plate: ViAC-CNP-66
  • Document Reference: DViACCNW0001-03 (datasheet), DViACCNW1001-03 (installation manual)

Downloads

Additional information

Device Type

System Type

Colour

Environment