Summary

The Lexicomm ViLX-IPA2 is an IP66 rated Type A EVCS (Emergency Voice Communications System) outstation designed specifically for use in outdoor or exposed areas. This robust weatherproof solution provides secure, bi-directional, full duplex voice communication to assist firefighters during emergencies in high-rise buildings or large sites where radio communication cannot be guaranteed to work due to interference from fire plasma.

Fully compliant with BS 5839-9:2021, which covers the design, installation and operation of fire telephones and disabled refuge systems in buildings, the ViLX-IPA2 is designed to be used by trained staff such as fire marshals and stewards in outdoor environments. All LexiComm Emergency Voice Communications Systems are designed to comply fully with the requirements of BS 5839-9:2021 for use as a fire telephone system, disabled refuge system, or as a combined system when both applications are required.

The outstation is supplied within a compact IP66 enclosure with texture painted steel construction in RAL 7035 finish, which is externally signed as required by Building Regulations Approved Document B. The enclosure is opened by operation of a lever lock (twist lock) or optional key lock, exposing the handset and allowing a call to be made. The system is compatible with Lexicomm standalone and network EVCS systems and includes an induction loop in the handset for hearing impaired users, compliant with EN 60118-4:2015+A1:2018. A Visual Indication Device (VID) is available as an option for steward telephone system applications.

Features

  • IP66 weatherproof enclosure for outdoor and exposed area installations
  • Type A outstation as defined in BS 5839-9:2021
  • Designed for use by trained staff in outdoor environments
  • Suitable for fire marshals and stewards
  • Surface mount installation only
  • Fully monitored to BS 5839-9:2021 standards
  • Red status LED for visual operational indication
  • Induction loop in handset for hearing impaired users
  • Induction loop compliant to EN 60118-4:2015+A1:2018
  • Optional VID (Visual Indication Device) available for steward telephone systems
  • Twist lock or key lock access options
  • Compact IP66 enclosure design
  • Texture painted steel construction
  • RAL 7035 painted finish
  • External signage as required by Building Regulations Approved Document B
  • Lever lock operation to access handset (standard)
  • Optional key lock for restricted access
  • Compatible with Lexicomm standalone and network EVCS systems
  • Full duplex bi-directional voice communication
  • Type A outstation locations per Building Regulations Approved Document B
  • Locations per BS 9999:2017 guidance
  • Stewards telephone locations per FSADC design guide
  • Mounted at 1300-1400mm height for BS 5839-9:2021 compliance
  • IP66 cable glands required and must be correctly tightened
  • Screw seals must be correctly fitted to maintain IP rating
  • Bare metal from drilling must be treated with antioxidant primer
  • Enhanced fire resistant cable up to 500m from panel
  • EOL device fitted for line monitoring
  • Dimensions: 300mm x 150mm x 130mm to handle front
  • Weight: 2.8kg

FAQs

What is the ViLX-IPA2 designed for?

The ViLX-IPA2 is a Type A EVCS outstation specifically designed for use in outdoor or exposed areas where weatherproof protection is required. It is intended for use by trained staff such as fire marshals and stewards in outdoor environments, providing reliable emergency communications where standard internal outstations would not be suitable.

What does the IP66 rating mean?

IP66 is a high level of ingress protection that provides complete protection against dust (solid particles) and protection against powerful water jets from any direction. This rating ensures the ViLX-IPA2 can operate reliably in outdoor conditions including rain, dust, and harsh weather environments.

What is the difference between twist lock and key lock options?

The standard ViLX-IPA2 features a twist lock (lever lock) that can be operated by any user to access the handset. The optional key lock version restricts access to authorized personnel only, requiring a key to open the enclosure and use the telephone. The key lock option is suitable for locations where controlled access is required.

What is the VID option?

VID (Visual Indication Device) is an optional feature available for steward telephone system applications. It provides high-intensity visual notification when the phone is ringing, complementing the audible alert and ensuring calls are not missed in noisy outdoor environments such as sports grounds.

What height should the ViLX-IPA2 be mounted at?

The ViLX-IPA2 unit should be mounted at a height of 1300mm to 1400mm from the centre line to the finished floor level to comply with the requirements of BS 5839-9:2021.

What special installation considerations are required for IP66 rating?

To maintain the IP66 rating: ensure all cable glands meet IP66 standards and are correctly tightened; when drilling holes for cable access, treat any bare metal with antioxidant primer; ensure all mounting holes have screw seals correctly fitted. Failure to follow these requirements will compromise the IP rating of the enclosure.

Where should Type A outstations be located?

Type A outstations should be placed in fire telephone locations as described in Building Regulations Approved Document B and BS 9999:2017, or in stewards telephone locations as described in the FSADC design guide. The ViLX-IPA2 is particularly suitable for outdoor locations within these guidelines.

What cabling is required?

Enhanced fire resistant cable (1mm or 1.5mm) is recommended, which can run up to 500m from the compatible panel. All cable entry points must use IP66 rated cable glands that are correctly tightened to maintain the weatherproof integrity of the enclosure.

Does the ViLX-IPA2 support hearing impaired users?

Yes, the ViLX-IPA2 includes an induction loop in the handset specifically for hearing impaired users, compliant with EN 60118-4:2015+A1:2018 standards.

Is the ViLX-IPA2 compatible with all Lexicomm systems?

Yes, the ViLX-IPA2 is compatible with both Lexicomm standalone and network EVCS systems, providing flexibility for different installation configurations.

What standards does the ViLX-IPA2 comply with?

The ViLX-IPA2 is fully compliant with BS 5839-9:2021 (emergency voice communication systems), BS 9999:2017 (fire safety code of practice), and EN 60118-4:2015+A1:2018 (hearing aid compatibility). It also meets EMC standards EN 55035:2017+A11:2020 and EN 55032:2015+A1:2020, plus LVD standard EN IEC62368-1:2020+A11:2020.

Specifications

  • Product Code: ViLX-IPA2
  • Product Type: IP66 Type A Outstation
  • IP Rating: IP66 (weatherproof)
  • Outstation Classification: Type A EVCS Outstation per BS 5839-9:2021
  • Application: Outdoor or exposed areas
  • Intended Users: Trained staff (fire marshals, stewards)
  • Height: 300mm
  • Width: 150mm
  • Depth: 130mm to handle front
  • Weight: 2.8kg
  • Material: Texture painted Steel
  • Finish: Painted RAL 7035
  • Enclosure Type: Compact IP66 rated
  • Access Mechanism: Twist lock (lever lock) or optional key lock
  • Status Indication: Red status LED
  • Induction Loop: Induction loop in handset
  • Induction Loop Compliance: EN 60118-4:2015+A1:2018
  • Visual Indication Device (VID): Available as option for steward telephone systems
  • Mounting Type: Surface mount
  • Installation Height: 1300mm to 1400mm from centre line to finished floor level
  • Communication Type: Full duplex bi-directional
  • Monitoring: Fully monitored to BS 5839-9:2021
  • Compatible Systems: Lexicomm standalone and network EVCS systems
  • External Signage: As required by Building Regulations Approved Document B
  • EOL Device: Fitted
  • Recommended Cable Type: Enhanced Fire Resistant
  • Recommended Cable Size: 1mm or 1.5mm
  • Maximum Cable Distance: 500m from compatible panel
  • Cable Gland Requirement: IP66 rated, correctly tightened
  • Installation Requirements: Screw seals correctly fitted, bare metal treated with antioxidant primer
  • EMC Compliance: EN 55035:2017+A11:2020, EN 55032:2015+A1:2020
  • LVD Compliance: EN IEC62368-1:2020+A11:2020
  • Product Family Standards: BS 5839-9:2021, BS 9999:2017, EN 60118-4:2015+A1:2018
  • Location Standards: Building Regulations Approved Document B, BS 9999:2017, FSADC design guide
  • Document Reference: DViLXIPA0001-02
  • Manufacturer: Vox Ignis
  • Company Registration: 8892407