Solo A5 Smoke Detector Tester Aerosol 250ml (Flammable)
£15.23 (inc VAT: £18.28)
Summary
Solo A5 (SOLOA5-001) is a 250ml smoke detector test aerosol for functional smoke detector testing, delivering simulated smoke particles into the sensing chamber via the detector vents when used with a Solo 330 or Solo 332 dispenser.
It is positioned as an everyday smoke detector testing spray for routine fire alarm testing, maintenance and inspection work, and has been introduced as a replacement option for the earlier Solo A3 aerosol range.
Solo A5 is supplied as an extremely flammable, pressurised aerosol and should be handled and stored in line with aerosol safety guidance, including keeping it away from ignition sources and avoiding exposure above 50°C.
Features
- Smoke detector testing spray for functional activation tests
- Delivers simulated smoke particles to replicate smoke conditions during testing
- Designed for use with Solo 330 and Solo 332 aerosol dispensers
- Replacement option for the Solo A3 aerosol range
- Suitable for routine fire alarm testing, servicing and planned maintenance
- Detector manufacturer approved for use on installed smoke detectors
- Range designed to support compliance with current regulations
- UL certified listing commonly referenced for the Solo smoke testing system
- Can also be used as a hand held test aerosol where appropriate
- 250ml pressurised aerosol canister
FAQ
What is Solo A5 used for
Solo A5 is used for smoke detector functional testing by introducing simulated smoke particles through the detector vents and into the sensing chamber to confirm correct activation.
Which dispensers are compatible with Solo A5
Solo A5 is designed to fit directly into the Solo 330 and Solo 332 aerosol dispensers.
Is Solo A5 a smoke detector test spray or test gas
It is a smoke detector test aerosol spray used to simulate smoke conditions for activation testing, commonly referenced as test aerosol or test gas in product listings.
Is Solo A5 intended to replace Solo A3
Yes, Solo A5 is widely described as being designed to replace the Solo A3 aerosol range for everyday smoke detector testing, with non flammable alternatives available in the Solo range where required.
Is Solo A5 flammable
Yes, it is classified as an extremely flammable aerosol in a pressurised container.
How should Solo A5 be stored
Store away from heat and ignition sources, protect from sunlight, and do not expose the canister to temperatures exceeding 50°C.
What is the UN number for transport
The transport UN number is UN 1950.
Specifications
- Product Name: Solo A5 Smoke Detector Test Aerosol
- Intended Use: Smoke detector functional testing
- Aerosol Type: Smoke detector testing spray
- Canister Size: 250ml
- Compatibility: Solo 330 and Solo 332 dispensers
- Classification: Aerosol 1
- Hazard Statements: H222 extremely flammable aerosol, H229 pressurised container may burst if heated
- Un Number: UN 1950
- Transport Class: 2.1
- Storage Temperature Limit: Do not exceed 50°C
- Appearance: Aerosol
- Colour: Colourless
- Odour: Characteristic
- Flash Point: Below 0°C
- Vapour Pressure: 3.8 bar at 20°C
- Density: 0.58 g/cm³ at 20°C
- Solubility In Water: Immiscible
Downloads
- Manufacturer Part Number: SOLOA5-001
- Product Type: Smoke Detector Test Aerosol
- Canister Size: 250ml
- Compatibility: Solo 330 and Solo 332 aerosol dispensers
- Application: Smoke detector functional testing
- Hazard Classification: Aerosol 1
- Hazard Statements: H222 extremely flammable aerosol, H229 pressurised container may burst if heated
- Un Number: UN 1950
- Transport Class: 2.1
- Storage Temperature Limit: Do not exceed 50°C
- Appearance: Aerosol
- Colour: Colourless
- Odour: Characteristic
- Flash Point: Below 0°C
- Initial Boiling Point: -44°C
- Vapour Pressure: 3.8 bar at 20°C
- Density: 0.58 g/cm³ at 20°C
- Solubility In Water: Immiscible
- Hazardous Ingredients: Butane, Propane, Ethanol
Additional information
| Weight | 0.4 kg |
|---|---|
| Stimulus Type | |
| Device Type |