Shopping Basket

0 Items

Subtotal £0.00

AMX Graphical Fire Alarm Management

SKU: AMX-Graphical-Fire-Alarm-Management
SKU: AMX-Graphical-Fire-Alarm-Management Category: Brand:

Summary

The Kentec AMX is a powerful and sophisticated fire alarm monitoring software solution designed for building managers who need to fully monitor and control fire detection systems on large public sites. When time is of the essence during a fire event, this comprehensive tool provides an all-encompassing fire risk and incident management system that plays a crucial role in safeguarding people, vitally important information and property.

AMX enables site managers to respond quickly to fire events through visual fire management capabilities. The system can automatically switch to the area on a site map where a fire device has been activated, allowing operators to quickly view an event and begin immediate investigation. Information displayed can be provided to emergency services to direct them to the required location, ensuring the fastest possible response during critical situations.

The software supports multiple PC connections through TCP/IP groups and offers both text-based alarm reporting and full device level graphics capability. With powerful event log filtering and reporting, configurable control buttons, and the ability to perform device and zone disablements and enablements, AMX provides a complete fire management solution for modern building environments.

Features

  • Monitor multiple alarm networks simultaneously
  • Supports multiple PC connections through TCP/IP groups
  • Text based alarm reporting or full device level graphics capability
  • Remote control of alarm systems
  • Clear and concise action messages for each alarm event
  • Fully configurable using engineer access
  • Powerful event log filtering and reporting
  • Configurable control buttons for quick access to common functions
  • Full site map navigation with automatic switching to alarm locations
  • Visibility of device analogue levels for enhanced monitoring
  • Perform device and zone disablements and enablements remotely
  • Up to 2,000 user accounts with customizable access levels
  • Three user access levels: Operator, Manager, and Engineer
  • Comprehensive history logs including event, control, isolation, user and system history
  • Each log can store up to 32,000 events per day with unlimited retention
  • Event categorization as general alarm, false alarm or test alarm
  • Supports up to 64 panels in a network
  • Up to 32,000 graphics pages supported
  • Compatible with multiple graphics file formats (GIF, JPG, BMP, WMF)
  • Audio alert capability with Windows WAV file support
  • Multiple workstation support using existing IP infrastructure
  • Manufactured in the UK with global technical support

FAQs

What fire alarm panels is AMX compatible with?

AMX is compatible with Kentec Taktis EN & UL, Syncro AS and Elite RS panels, as well as Hochiki HFP and FireNET Plus panels. For Taktis and Latitude panels, connection is via Ethernet using a Media Gateway card (K794) which must be installed in slot F of the panel. For Syncro AS, Elite RS, HFP and FireNET Plus panels, connection is via RS232 serial communication using the panel’s printer port. Note that Elite RS/FireNET Plus panels fitted with a dialer cannot be connected to the graphics system.

How many user accounts can be created in AMX?

AMX supports up to 2,000 user accounts, each with unique login credentials. Users can be assigned one of three access levels: Operator (basic features for day-to-day operation), Manager (advanced features for configuration, backups, and user management), or Engineer (full access for installation, commissioning and maintenance).

What are the minimum PC requirements for running AMX?

The minimum PC requirements are: Intel Pentium 5 processor or better, Windows 10 Professional operating system, 8GB RAM minimum (16GB recommended), 320GB minimum disk space (larger is better), 1920 x 1080p monitor, standard speakers or monitor with built-in speakers, standard 2 button mouse with scroll wheel, minimum 1 LAN port, and minimum 4 USB ports. A Windows compatible A4 printer (laser or inkjet) is also required.

What types of history logs does AMX maintain?

AMX maintains five types of history logs: Event History (all alarms, faults, resets, and services with categorization options), Control History (all control actions initiated via the software), Isolation History (all isolations initiated via the software), User History (user login and logout records), and System History (software shutdowns, user actions summary, configuration changes and operating faults). Each log can store up to 32,000 events per day with no limit on retention duration.

Can AMX monitor multiple fire alarm panels simultaneously?

Yes, AMX can monitor multiple alarm networks simultaneously and supports up to 64 panels in a network. The system supports multiple PC connections through TCP/IP groups, allowing for distributed monitoring across a facility using existing IP infrastructure.

What connection methods are available for linking AMX to fire panels?

Connection methods depend on the panel type and distance. For Taktis/Latitude panels, connection is via Ethernet using a CAT 5 cable to the Media Gateway card. For Syncro AS/HFP/Elite RS/FireNET Plus panels, connection is via RS232 serial. For distances up to 15m (50ft), use the S187 Software Download Lead with an isolated USB-RS232 converter. For distances up to 1km (3280ft), use the S572 USB to RS232 converter kit which includes RS232-485 interface card and isolated RS485 to USB adaptor.

What is the default password for a newly installed AMX system?

The default password for a newly installed AMX system is “Pixmore7” (case sensitive), which provides full engineer access. It is strongly recommended to set up one or more unique Engineer level users at installation and delete the default password. Engineer level passwords should be kept safe as there are no back-door passwords available.

What control functions can be performed remotely through AMX?

When using Syncro Enhanced node type settings, AMX allows the following remote control actions: Reset Panel, Silence Network Alarms, Disable/Enable Device, Disable/Enable Zone, Evacuate Panel, Alert Panel, Silence Panel Alarms, Evacuate Network, Reset Network, and Alert Network. This provides comprehensive remote management capabilities for fire alarm systems.

Specifications

  • Product Name: AMX Fire Alarm Monitoring Solution
  • Manufacturer: Kentec Electronics
  • Minimum Processor: Intel Pentium 5 or better
  • Operating System: Windows 10 Professional
  • Minimum Memory: 8GB (16GB recommended)
  • Minimum Disk Space: 320GB (larger recommended)
  • Monitor Resolution: 1920 x 1080p
  • Audio Requirements: Standard speakers or monitor with built-in speakers minimum
  • Pointing Device: Standard 2 button mouse with scroll wheel
  • Printer: Any Windows compatible A4 printer – Laser or Inkjet
  • Minimum Lan Ports: 1
  • Minimum Usb Ports: 4
  • Maximum User Profiles: Up to 2,000
  • Maximum Graphics Pages: Up to 32,000
  • Maximum Text Pages: Up to 2,129,698,800
  • Recommended Graphics Resolution: 1024 x 768
  • Graphics Files Supported: GIF, JPG, BMP, WMF
  • Sound Files Supported: Windows WAV files
  • History Logs Capacity: Up to 32,000 events per day
  • History Log Retention: Unlimited
  • Maximum Panels In Network: 64
  • Loops Per Panel: 1 or 2
  • Devices Per Loop: 127 Hochiki (254 inc. sounder base addresses), 126 Apollo
  • Rs232 Port Range: COM1 to COM255
  • Rs232 Baud Rate: 19200
  • Rs232 Parity: None
  • Rs232 Data Bits: 8
  • Rs232 Stop Bit: 1
  • Maximum Rs232 Distance: Approximately 15 metres (50ft)
  • Maximum Rs485 Distance: Up to 1km (3280ft)
  • Compatible Panels: Taktis EN & UL, Syncro AS, Elite RS, HFP, FireNET Plus
  • Connection Type Taktis/latitude: Ethernet via Media Gateway card (K794)
  • Connection Type Syncro/elite/hfp/firenet: RS232 serial via printer port
  • Network Communication: TCP/IP groups with multiple PC support
  • User Access Levels: Operator, Manager, Engineer
  • Alarm Types Supported: Fire Alarm, Security Alarm, Pre Alarm, Test Mode, Disablement, Tech Alarm, Fault
  • Licence Type: Hardware USB dongle
  • Country Of Manufacture: United Kingdom
  • Certifications: UKCA, CE marked, ROHS compliant
  • Approvals: EN54, EN12094, UL, FM, NFPA

Downloads

Additional information

Device Type

Protocol

,

Nodes

1, 2 to 4, 5 to 24, 25 to 64

Related Products