EMS FireCell Wireless Heat Detector | Choice of A1R (Rate of Rise) or CS (Fixed Temp)
£32.31
Summary
The EMS FireCell wireless heat detectors comprise two detector head variants designed for different thermal detection applications when combined with compatible FireCell wireless bases. The FCX-175-001 A1R model provides rate of rise heat detection certified to EN54-5 Class A1R, responding to rapid temperature increases typical of fast-developing fires, with application temperatures from 25°C to 50°C and static response between 54°C and 65°C. The FCX-176-001 CS model offers fixed temperature heat detection certified to EN54-5 Class CS, suited for higher ambient temperature environments with application range from 55°C to 80°C and static response between 84°C and 100°C. Both detector heads must be paired with compatible wireless bases (FCX-170-001, FCX-170-101, FCX-191-000, or FCX-191-200) to create complete wireless heat detection systems with individual addressing at the fire control panel.
Both heat detector variants feature integrated fire indication LEDs for immediate visual alarm confirmation, anti-tamper locking mechanisms securing the detector to the wireless base, and the FasTest maintenance feature enabling rapid functional testing during service visits. The detector heads alone provide the thermal sensing element; wireless communication capability, battery power, and system integration are delivered through the separately purchased wireless base. This modular approach allows system designers to select the appropriate heat detection class for each application while choosing between standard detector bases or sounder bases depending on local alarm indication requirements.
Manufactured to rigorous EN54-5 standards for heat detection performance, both models carry third-party certification with DoP references 0359-CPR-0015 and 0359-CPR-0041, alongside CE, UKCA, and BOSEC approvals. Operating across temperatures from -10°C to 55°C with IP23 environmental protection for indoor applications, the detectors integrate seamlessly with EMS FireCell systems including the Fusion RLM. When installed on compatible wireless bases, the complete assemblies provide dual band 868 MHz communication with wireless ranges up to 1250 metres in clear line of sight conditions, delivering reliable wireless heat detection for commercial, industrial, and residential fire alarm installations.
Features
- Two detector variants: A1R rate of rise (FCX-175-001) and CS fixed temperature (FCX-176-001)
- Heat detection certified to EN54-5
- Detector-only components requiring compatible wireless base
- Compatible with FCX-170-001, FCX-170-101, FCX-191-000, FCX-191-200 bases
- A1R Class: typical application temperature 25°C, maximum 50°C
- A1R Class: static response minimum 54°C, typical 57°C, maximum 65°C
- A1R Class: rate of rise detection for fast-developing fires
- CS Class: typical application temperature 55°C, maximum 80°C
- CS Class: static response minimum 84°C, typical 90°C, maximum 100°C
- CS Class: fixed temperature detection for high ambient temperature areas
- Fire indication LED for visual alarm confirmation
- Anti-tamper locking mechanism prevents unauthorized removal
- FasTest maintenance feature for rapid testing and verification
- Operating temperature range from -10°C to 55°C
- IP23 environmental protection for indoor use
- Compact dimensions: 113mm diameter x 76mm depth
- Lightweight construction at 0.4kg
- Third-party EN certified for compliance assurance
- DoP certification: 0359-CPR-0015 and 0359-CPR-0041
- CE, UKCA, and BOSEC approved
- Compatible with EMS FireCell system and Fusion RLM
- Enables individual addressing when paired with wireless base
- Dual band 868 MHz operation when installed on compatible base
- Auto-adjusting power output capability through wireless base integration
- Wireless range up to 1250 metres when installed on compatible base
- Suitable for commercial, industrial, and residential applications
- Ideal for retrofit installations and areas where cabling is impractical
- Quick and easy installation with twist-lock mounting
FAQs
Which heat detector model should I choose – A1R or CS?
Select the FCX-175-001 A1R rate of rise detector for normal ambient temperature environments (typically 25°C, maximum 50°C) where rapid fire development detection is required, such as offices, residential areas, circulation spaces, and general commercial buildings. The A1R responds to both rate of temperature rise and fixed temperature (57°C typical), providing early warning of fast-developing fires. Choose the FCX-176-001 CS fixed temperature detector for areas with higher normal ambient temperatures (typically 55°C, maximum 80°C) where rate of rise detection could cause false alarms, such as kitchens, boiler rooms, plant rooms, laundries, and manufacturing facilities with heat-producing processes. The CS responds at a higher fixed temperature (90°C typical), preventing nuisance alarms from normal operational heat while reliably detecting fire conditions.
What wireless bases are compatible with these heat detectors?
Both the FCX-175-001 (A1R) and FCX-176-001 (CS) heat detector heads must be used with one of the following compatible FireCell wireless bases: FCX-170-001 (standard wireless detector base), FCX-170-101 (wireless detector base variant), FCX-191-000 (wireless sounder base), or FCX-191-200 (wireless sounder base variant). The detector heads alone do not provide wireless communication capability or power – they must be mounted on a compatible base that provides the 868 MHz wireless interface, battery power (6 x AA alkaline), and communication with the FireCell control panel. Standard bases provide detection-only functionality, while sounder bases add integrated audible alarm capability at the detection point for enhanced local warning.
Can heat detectors be used instead of smoke detectors?
Heat detectors should not automatically replace smoke detectors – the appropriate detector type depends on the specific application and fire risk assessment. Smoke detectors (like the FCX-177-001 optical) provide earlier fire detection by sensing smoke particles before significant temperature rise occurs, making them essential for sleeping areas, escape routes, and most general areas. Heat detectors are specified for environments where smoke detectors would cause false alarms due to steam, cooking fumes, dust, or other airborne particles, or in areas with very high ceilings where smoke would not reach detectors quickly. Many systems use both detector types strategically – smoke detectors for early warning in critical areas and heat detectors in challenging environments where smoke detection is impractical.
What is the difference between the A1R and CS EN54-5 classifications?
EN54-5 defines different heat detector classes based on their response characteristics and intended applications. Class A1R detectors combine rate of rise sensing (responding to rapid temperature increases of typically 10°C per minute) with fixed temperature response, providing early detection of fast-developing fires while maintaining a backup static response temperature. Class CS detectors are fixed temperature devices that respond when ambient temperature reaches a specific threshold, offering reliable detection in environments with higher normal temperatures or gradual temperature changes. The “A” in A1R indicates a lower response temperature range suitable for normal environments, while “CS” indicates a higher static temperature classification for hotter ambient conditions where lower-temperature detectors would false alarm during normal operations.
How does the FasTest maintenance feature work on heat detectors?
The FasTest maintenance feature enables rapid functional testing of the heat detector heads during routine service visits without requiring specialized test equipment or heat application. Service engineers can quickly verify the detector’s thermal sensing capability, alarm response, LED indication, and communication with the system through the wireless base using simplified test procedures. This streamlined testing process significantly reduces maintenance time compared to traditional heat detector testing methods that often require heat sources or aerosols, particularly valuable in large installations with numerous detectors requiring periodic verification. FasTest ensures the detector meets EN54-5 performance requirements while minimizing system downtime and service costs.
Specifications
- Product Code A1R: FCX-175-001
- Product Code CS: FCX-176-001
- Product Type: Heat detector heads only
- Detection Technology: Thermal sensing (A1R: rate of rise and fixed; CS: fixed temperature)
- EN54-5 Classification A1R: Class A1R (rate of rise with fixed temperature backup)
- EN54-5 Classification CS: Class CS (fixed temperature)
- Application Temperature A1R Typical: 25°C
- Application Temperature A1R Maximum: 50°C
- Static Response Temperature A1R Minimum: 54°C
- Static Response Temperature A1R Typical: 57°C
- Static Response Temperature A1R Maximum: 65°C
- Application Temperature CS Typical: 55°C
- Application Temperature CS Maximum: 80°C
- Static Response Temperature CS Minimum: 84°C
- Static Response Temperature CS Typical: 90°C
- Static Response Temperature CS Maximum: 100°C
- Required Components: Compatible wireless base (sold separately)
- Compatible Bases: FCX-170-001, FCX-170-101, FCX-191-000, FCX-191-200
- Operating Temperature: -10°C to 55°C
- Environmental Protection: IP23, indoor use only
- Dimensions: 113mm x 76mm (Ø x D)
- Weight: 0.4kg (complete assembly with base)
- DoP Reference: 0359-CPR-0015 & 0359-CPR-0041
- EN Certification: EN54-5 (heat detection), EN54-25 (wireless, via base)
- Approvals: CE, UKCA, BOSEC
- System Compatibility: EMS FireCell system, Fusion RLM
- Wireless Operation: Via compatible base (868 MHz dual band)
- Wireless Range: Up to 1250m (when installed on compatible base, clear line of sight)
- RF Power Output: 0 to 14 dBm auto-adjusting (via wireless base)
- Power Supply: Via wireless base (6 x AA alkaline batteries)
- Compatible Batteries: Panasonic LR6AD Powerline or Varta 4006 Industrial (via base)
- Visual Indication: Fire indication LED
- Anti-Tamper: Locking mechanism
- Maintenance Feature: FasTest
- Addressing: Individual addressing at control panel (via wireless base)
- Signalling Protocol: X protocol (via wireless base)
Datasheet
- Datasheet (Adobe PDF)