Emergency Lighting: The Basics

What is emergency lighting and what is it for?

Emergency lighting provides light when the normal lighting supply fails. Emergency escape lighting is the part that helps people find exits, follow escape routes and see safety equipment when the normal lights are unavailable.

Depending on the building, a system may need to illuminate stairs, changes of level, exit signs, fire alarm call points and firefighting equipment. The premises’ risk assessment and lighting design determine where fittings are needed. See the government fire risk assessment guide for offices and shops for examples.

How do emergency lights work?

Emergency fittings use a backup supply when the normal lighting supply fails. A self-contained fitting has its own rechargeable battery. A central battery system supplies multiple fittings from one battery source. Eaton’s emergency lighting guide explains both arrangements.

A fire alarm warns people. Emergency escape lighting helps them see the route if normal lighting fails. A fire alarm sounding and a lighting supply failing are separate events.

What types of emergency lighting are there?

Maintained and non-maintained describe how a fitting operates in normal use. Self-contained and central battery describe how it is powered in emergency operation.

  • Maintained: the emergency lamp can operate during normal use and stays lit from the emergency supply when the normal supply fails.
  • Non-maintained: the emergency lamp is normally off and comes on automatically when the normal lighting supply fails.

Emergency escape lighting helps people reach safety. Standby lighting allows normal activities to continue where the design calls for it. BSI’s summary of BS 5266-1:2025 also covers local area lighting.

How long do emergency lights last in a power cut?

Government guidance for offices and shops describes emergency escape lighting designed for one to three hours, with three hours a common design. Check the fitting’s rated emergency duration against the duration required for the premises.

Which emergency fitting should I choose?

  • Emergency bulkheads are surface-mounted fittings. Check the operating mode and IP rating for where the fitting will go.
  • Illuminated exit signs identify exits or indicate the direction of escape. Check the legend and viewing distance specified by the design.
  • Twinspot emergency lights use two heads to direct light. Check the fitting’s coverage against the lighting layout.

For a replacement, check the operating mode, rated duration, mounting and whether the fitting is self-contained or uses a central supply. Check that it suits the existing design before ordering.

Do emergency lights need testing?

Yes. The government offices and shops guide describes a monthly function test and an annual full-duration test. Self-test fittings can automate checks. Follow the manufacturer’s instructions for reviewing results and recording maintenance.

Browse Huvo’s emergency lighting range.