SenTRI VAD, Low Power Red Flash, Class C

£105.50 (inc VAT: £126.60)

Low Stock

SKU: SEN-S-VAD-LPR-R Category: Brand:

Summary

The SMS SEN-S-VAD-LPR-R is an addressable wall-mounted combined sounder and Visual Alarm Device (VAD) designed for integration with SMS SenTRI analogue addressable fire alarm systems. Featuring a red body construction with a red flash beacon, this standard performance unit delivers combined audible and visual fire alarm notification whilst maintaining efficient power consumption characteristics that maximise loop capacity and system design flexibility.

Certified to EN54-23 standard performance category (W3-8.5), the SEN-S-VAD-LPR-R provides essential visual alarm indication for occupants with hearing difficulties alongside traditional audible alarm signalling, ensuring comprehensive fire safety coverage that meets Equality Act 2010 accessibility requirements. The loop-powered addressable architecture eliminates the need for separate power supplies or notification appliance circuits, reducing installation complexity and enabling full monitoring and control from SenTRI control panels.

The device incorporates HandiLink infrared remote control compatibility, allowing volume adjustment during commissioning without physical access to the unit. With sound output of 103 dB(A) at 1 metre and IP21 ingress protection, the SEN-S-VAD-LPR-R delivers reliable performance across commercial, educational, and institutional applications whilst maintaining industry-leading efficiency with up to 72 combined sounder-VAD devices supported per loop on standard loop cards.

Features

  • EN54-23:2010 standard performance VAD certification (W3-8.5)
  • Combined sounder and visual alarm device in single unit
  • Addressable loop-powered operation for simplified installation
  • Low power consumption design enabling up to 72 devices per loop
  • Red body construction with red flash beacon
  • Sound output 103 dB(A) ±3 dB(A) at 1 metre
  • Compatible with SMS SenTRI analogue addressable systems
  • HandiLink infrared remote control for volume adjustment
  • Standard tone and bell sound options available
  • Fully synchronised sound patterns and flash rate across loop
  • Active monitoring of sounder and VAD circuits
  • IP21 ingress protection rating for standard applications
  • Wall-mounted configuration for optimal coverage distribution
  • Integrates with SenTRI ONE, TWO, and FOUR control panels
  • Two-wire loop connection reducing cabling requirements
  • Supports Equality Act 2010 accessibility requirements
  • Password-protected volume adjustment via control panel
  • 0.5Hz VAD flash frequency for compliant visual notification
  • LPCB approved to EN54-3, EN54-23, and EN54-17 standards
  • Operating temperature range -10°C to +50°C

FAQs

What is the difference between standard performance and high performance VAD models?

Standard performance VAD models like the SEN-S-VAD-LPR-R are certified to W3-8.5 coverage category under EN54-23, providing appropriate visual alarm indication for general fire alarm applications. High performance models offer adjustable intensity settings (high, medium, low) delivering increased light output and larger coverage areas (W-6.7-14 to W-5-9.5 categories). Standard performance models consume less current, allowing more devices per loop (up to 72 vs 38-47 for high performance), making them cost-effective for applications where enhanced coverage is not required.

How many SEN-S-VAD-LPR-R devices can be installed on a SenTRI loop?

The SEN-S-VAD-LPR-R low power consumption design allows up to 72 combined sounder-VAD devices per loop when using standard SenTRI loop cards. The enhanced 800mA loop card supports up to 70 combined sounder-VAD devices per loop whilst accommodating up to 200 total addressable devices including sensors, call points, and interfaces. Precise device counts should be calculated during system design using loop load design tools, considering the specific mix of devices and their current consumption in both standby and alarm conditions.

Can the sounder and VAD operate independently?

Yes, the SEN-S-VAD-LPR-R can be configured to operate the sounder and VAD independently through the SenTRI control panel programming. This flexibility allows the visual alarm to activate separately from the audible alarm if required by the fire safety strategy, enabling staged evacuation procedures or specific alert conditions where visual-only or audible-only notification is appropriate. Both outputs remain fully monitored and synchronised with other devices on the loop regardless of configuration mode.

What is HandiLink infrared remote control functionality?

HandiLink is an infrared remote control system that enables volume adjustment of SenTRI sounders during commissioning without requiring physical or mechanical access to the device. The commissioning engineer can adjust sound levels from floor level up to 3 metres away from the device, reducing installation time and eliminating the need for ladders or scaffold access during final system setup. This feature must be enabled at the control panel with password protection to prevent accidental or malicious adjustment, and is disabled automatically after commissioning is complete.

Is the SEN-S-VAD-LPR-R suitable for outdoor applications?

No, the SEN-S-VAD-LPR-R has an IP21 ingress protection rating designed for standard indoor applications in commercial, educational, and institutional premises. For outdoor applications or environments requiring enhanced environmental protection, the SenTRI range includes EP (Environmentally Protected) variants with IP66 rating that provide resistance to heavy rain, dust ingress, and temporary water jets. The EP range includes models such as SEN-S-VAD-HPR-EP-R for outdoor or harsh environment installations where increased protection is necessary.

What fire alarm tones are available on the SEN-S-VAD-LPR-R?

The SEN-S-VAD-LPR-R supports standard tone patterns and bell tone options that can be configured through the SenTRI control panel commissioning software. All tones are fully synchronised across the loop to prevent confusion during evacuation and comply with fire safety signalling requirements. The standard tone provides a distinctive alert signal, whilst the bell tone option is particularly useful in educational environments for class change or alternative alert scenarios. Tone selection and synchronisation parameters are managed centrally through the control panel cause and effect programming.

Specifications

  • Model Number: SEN-S-VAD-LPR-R
  • Product Type: Addressable combined sounder and visual alarm device
  • Mounting Type: Wall mounted
  • Body Colour: Red
  • VAD Flash Colour: Red
  • VAD Performance Category: Standard performance (W3-8.5)
  • Power Type: Low power
  • Operating Mode: Loop powered addressable
  • System Compatibility: SMS SenTRI analogue addressable systems
  • Sound Output: 103 dB(A) ±3 dB(A) at 1 metre
  • VAD Flash Frequency: 0.5Hz
  • Maximum Devices Per Loop: 72 combined sounder-VADs (standard loop card)
  • Ingress Protection: IP21
  • Operating Temperature: -10°C to +50°C
  • Dimensions: 112mm (W) x 112mm (H) x 75mm (D)
  • Weight: Approximately 0.3kg
  • IR Control Operating Distance: Up to 3 metres
  • Compliance Standards: EN54-3, EN54-23:2010, EN54-17
  • Certifications: LPCB approved
  • Manufacturer: SMS by Honeywell

Downloads

Additional information

Weight0.30 kg
System Type

Device Type

,

Environment

Colour

Protocol

Short Circuit Isolator

Hazardous Applications

Marine Applications