Fike

Fike Twinflex Pro 2, 4 or 8 Zone Fire Alarm Panel

SKU: 64896c4de303
SKU: 64896c4de303 Categories: , Brand:

You may also need

Key features

  • 2 wire system (detectors, sounders & call points wired on the same zone wiring)
  • Available in 2, 4 or 8 zone version (4 zone can be expanded to 8)
  • LCD display allowing zones to be labeled (“Ground Floor”, “1st Floor”, etc)

Downloads

Summary

Choose the Fike Twinflex Pro 2 panel by its part number. Select 2 zones for 505-0002, 4 zones for 505-0004 or 8 zones for 505-0008 in the Zones menu.

View full overview Show less

The panel uses Fike’s Twinflex two-wire protocol. Compatible detectors, sounders and call points can share the zone wiring. Fike specifies up to 32 devices per zone, subject to the device loading limit, and lists two 12 V 3.3 Ah backup batteries for the panel. Check the system’s device loading and standby battery calculation for your installation.

For a replacement or extension, confirm the existing panel, devices and any expansion card against the engineering and commissioning manual. The Twinflex Pro 2 user guide covers everyday operation.

Features

  • 2-wire fire alarm system
  • Front panel LCD display (4 lines x 20 characters)
  • Differentiates between call point and detector alarms
  • Event log storing up to 500 events
  • Up to 32 devices per zone
  • Compatible with all previous Fike Twinflex devices

Approvals

  • CE
  • BS5839 & EN54 Part 4 (LPCB)

Specifications

  • Dimensions : 331x331x99mm
  • Weight (Excluding Batteries) :
    • 2 Zone : 2.25kg
    • 4 Zone : 2.28kg
    • 8 Zone : 2.36 kg
  • Construction : V0 rated ABS
  • IP Rating : IP 30
  • Cable Entry : 13 x 20mm knockouts 1 x 50mm x 50mm pull out tab
  • Cable Type : 2 core 1.5mm2 screened fire rated cable, 500m (max per zone)
  • Devices Per Zone : Up to 32 Devices dependant on Device Loading Units (DLUs) not exceeding the stated maximum loading
  • Device Protocol : TWINFLEX® V3 + TWINFLEX®pro
  • Monitored Sounder Circuits :
    • 2 Zone : Up to 2 (250 mA)
    • 4 Zone : Up to 2 (250 mA)
    • 8 Zone : Up to 2 (200 mA)
  • Monitored Relay Circuits :
    • 2 Zone : Up to 2 (250 mA)
    • 4 Zone : Up to 2 (250 mA)
    • 8 Zone : Up to 2 (200 mA)
  • Relays On Board : Common fire and common fault
  • Operating Standard : BS EN54-2 & 4
  • Operating Temperature : 5°C to 40°C
  • Mains Supply Range : 230VAC, +10%, -15%, 50/60Hz
  • Event Log : 500 Events
  • Zone Labels : 12 Characters

FAQ

Which part number should I select?

Fike lists 505-0002 for two zones, 505-0004 for four zones and 505-0008 for eight zones. Match the part number on your specification or existing panel to the Zones option before ordering.

Can I use this panel to replace an older Twinflex or Twinflex Plus panel?

Check the existing panel model, device part numbers and any expansion cards against Fike’s engineering documentation. Fike lists separate current and legacy Twinflex documents so you can identify the right manual for your panel.

Which Twinflex Pro 2 manual do I need?

Use the user guide for day-to-day operation and the engineering and commissioning manual for device loading, configuration and commissioning.

OSP Configuration Software

The Twinflex Pro panels can be configure using the OSP Twinflex software. This Windows based program allows the system to be set up for each application from a laptop and configurations options include;

  • Panel Details
    • Panel Description – A panel description (up to 14 characters) may be allocated to the panel.
    • Panel Mode – The only available panel mode is Standard. This may change with future developments.
    • Panel Type – The Panel Type section indicates the number of zones available in the current panel (2, 4 or 8 zone).
    • Quiescent Display Text – You can set up four lines of user-definable text which is shown on the panel when it is in the start up condition. Only line 2 and 3 are indicated in a quiescent state. The default text is shown in the sample screen above.
    • Codes – The control panel access codes may be changed as required on this screen.
  • Delays & Timers Tab
    • Alarm Delays – An alarm delay can be programmed for selected zones with values between 0 and 5 minutes. An Alarm Confirmation delay may be set up so that when an alarm occurs, it is not immediately reported. The system will wait until the end of the delay time and then check that the alarm is still present. If it has cleared, the device which was in alarm will be reset and no further action need be taken. The delay time for alarm confirmation can be programmed from 1 – 5 minutes. This option cannot be used at the same time as alarm delay.
    • Panel Timers – You can program how often the service timer is to occur so that the end-user is prompted to call for a service. You can also specify a day and a time (hours and minutes on the 24 hour clock) for a weekly test to be performed on the panel. Leave the fields blank if you do not want a weekly test or un-tick the boxes provided.
    • Day/Night Mode – The Day / Night mode tab is shown below.
    • Pre-programmed Times (RTC) Enabled – You can set times throughout the week (hours and minutes on the 24 hour clock) for day/night mode to be operational by filling in the Days “From To” Table as shown in the tab. There can only be one such time range set up per day. You can also specify (using the zone tick boxes) which zones are to be disabled during the selected times. This allows you to disable smoke detection in a zone during the day but not at night.
    • Panel Input Event – With this option, you can configure the system so that day / night mode will follow any panel inputs set to day/night mode.
  • Panel Inputs Tab – A Panel Input can be configured as a Control Event, Remote Fire Event, a Technical Event, a Disablement, Day/Night timer input or left un-configured. Some actions can be latching or Non-latching.
  • Panel Outputs Tab
    • Non-Monitored Outputs 1 & 2 – On the Twinflex Pro panel there are two relay outputs (1 & 2). The configuration of these two outputs is fixed (Output 1 is common fire, Output 2 is common fault), however the description can be changed. A Common Fire Output is activated by any Fire on the system.
A Common Fault Output is activated by any Fault on the system.
    • Monitored Outputs – Two monitored outputs (numbered MO1 and MO2 may be configured so that they will be activated when certain conditions occur. Selection is made via radio buttons. Options are, remote sounders, remote fire & off (not configured).
  • Printer Tab
  • Zone Details Tab – This screen allows the zones to be turned on or turned off. If for example only 3 out of the 4 zones on a four zone panel are used, the unused zone can be turned off to prevent an EOL fault being reported. Any number of zones may be turned off and in any order. Also on this screen are the device type boxes. At present only the CP/DET should be used, the CP/SM/HT position should not be used. This will only be available when a new detector is released in the future.

System Requirements

  • A desktop or laptop PC running the Windows XP or Windows 7 operating system (32-bit versions) with at least 1GB RAM.
  • The PC must have a CD drive in order to install your software.
  • The PC must have a USB port for connection to the panel.
  • A USB interface lead for connection of the PC to the control panel.

Downloads

  • Software (Available Upon Request)
  • Manual (Adobe PDF)

Downloads

Additional information

Weight2.5 kg
System

Twinflex

Zones

2, 4, 8

Device Type

System Type

,