Summary
The Kentec Sigma XT+ Extinguishant Coincidence Unit (ECU) is a sophisticated fire suppression control system designed to provide EN12094-1, EN54-2 and EN54-4 compliant extinguishant control. Featuring two fully monitored inputs for connection to fire detection control equipment or addressable control modules, this versatile unit delivers comprehensive control capabilities for all extinguishing applications.
With its extensive range of programmable features and inputs/outputs, the Sigma XT+ ECU offers exceptional flexibility for system designers and installers. The unit incorporates dual extinguishant outputs that can be configured for main/reserve applications, ensuring maximum reliability and system redundancy. A built-in countdown timer displays the time until discharge in seconds, providing clear visual indication during critical sequences.
The system supports serially connected status units for reduced wiring costs and simplified installation, while offering up to 512 programmable input/output capabilities via optional plug-in expansion cards. Each unit is independently configurable through a simple code-based programming interface, making it suitable for a wide range of fire suppression applications where a fully featured control device is required.
Features
- Two fully monitored inputs for fire detection control equipment connection
- Dual extinguishant outputs with configurable main/reserve operation
- First and second stage sounder outputs with dedicated relay contacts
- 8-line, 40-character graphic LCD display for clear system information
- Discharge countdown timer with seconds display
- 3 programmable inputs for flexible system integration
- 5 programmable relay outputs for enhanced control
- Serial connection capability to status indicators
- Hard wired fire and fault routing for reliable operation
- Up to 512 programme input/output via optional expansion cards
- Code-based programming interface for easy configuration
- 230V AC or 110V AC mains input (link selectable)
- 24V DC power supply with 5.25A capacity
- Battery backup support up to 2 x 7Ah sealed lead acid
- Temperature compensated battery charging
- Multiple relay contacts for fire, fault, and stage operations
- Adjustable extinguishant release delay (0-60 seconds)
- Adjustable extinguishant release duration (60-300 seconds)
- RS485 communication for status indicators and ancillary boards
- Robust 1.2mm mild steel enclosure construction
FAQ
What fire detection systems is the Sigma XT+ compatible with?
The Sigma XT+ features two fully monitored inputs that can connect to fire detection control equipment or addressable control modules, making it compatible with most conventional and addressable fire detection systems.
How does the main/reserve facility work?
The dual extinguishant outputs can be configured for main/reserve applications, providing system redundancy. If the primary extinguishant system fails, the reserve system automatically activates to ensure continuous protection.
What is the maximum number of inputs and outputs available?
The base unit provides 3 programmable inputs and 5 programmable relay outputs. With optional plug-in expansion cards connected serially, the system can support up to 512 programmable input/output points.
How is the countdown timer displayed?
The system features an 8-line, 40-character graphic LCD display that shows the discharge countdown timer in seconds, providing clear visual indication of the time remaining until extinguishant release.
What power supply and battery backup options are available?
The unit operates on 230V AC or 110V AC mains supply (link selectable) with a 24V DC, 5.25A power supply. Battery backup supports up to 2 x 7Ah sealed lead acid batteries with temperature compensated charging.
Can multiple status indicators be connected?
Yes, the system supports serially connected status indicators via RS485 communication, reducing wiring costs and installation complexity whilst allowing comprehensive system monitoring across multiple locations.
Specifications
- Product Code: K21001M2
- Dimensions: 385mm (w) x 310mm (h) x 110mm (d)
- Construction: 1.2mm mild sheet steel surface mount enclosure
- IP Rating: IP30
- Finish: Epoxy powder coated
- Colour Lid & Box: BS 00 A 05 grey – fine texture
- Colours Control Plates & Labels: RAL 7047 light grey – satin
- Weight: 7kg
- Display: 8 lines of 40 characters graphic LCD
- Mains Input Supply Voltage: 230V AC 50/60Hz or 110V 50/60Hz (link selectable)
- Mains Supply Fuse: 250V, 3A, SB, 5
- Power Supply Rating: 24V, 5.25 A (nominal)
- Battery Type: 12V sealed lead acid (connected in series)
- Maximum Battery Capacity: 2 x Yuasa 7Ah
- Battery Charge Voltage: 27.6V DC nominal (temperature compensated)
- Battery Charge Current: Two stage, constant voltage, 1.25A maximum
- Load Fuse: 5A, self resetting
- Maximum Current Draw From Batteries: 7 Amps
- Aux 24V Output: Fused at 500mA with electronic fuse
- 1st And 2nd Stage Sounder Outputs: 21 to 28V DC fused at 1A with electronic fuse
- Relay Contact Rating: 5 to 30V DC 1A maximum for each
- Zone Quiescent Current: 0mA minimum, 2mA maximum
- Terminal Capacity: 0.5mm² to 2.5mm² solid or stranded wire
- Monitored Input End Of Line: 6K8 +/- 5% ½ W resistor
- Sounder Circuit End Of Line: 10K +/- 5% ¼ W resistor
- Extinguishant Output End Of Line: 1N4004 diode
- Extinguishant Release Output: 21 to 28V DC. Fused at 1A
- Extinguishant Release Delay: Adjustable 0 to 60 seconds (+/- 10%)
- Extinguishant Release Duration: Adjustable 60 to 300 seconds
- Status Indicator Connection: Two wire RS485 (EIA-485 specification)
- Status Unit Power Output: 21 to 28V DC, Fused at 500mA with electronic fuse
- Approvals: EN12094-1, EN54-2 and EN54-4
Downloads
- Datasheet (Adobe PDF)
Additional information
| Weight | 15 kg |
|---|---|
| Device Type | |
| Networkable |