The Kentec Sigma XT is the industry leading extinguishant releasing panel, installed extensively in thousands of premises globally, offering outstanding value and performance for all small to medium fixed firefighting installations. This robust and reliable control system represents decades of engineering excellence, providing comprehensive fire suppression control with unmatched flexibility and ease of installation.

With three detection zones as standard, the Sigma XT allows extinguishant release to be configured to activate from any single zone or any combination of detection zone inputs. This versatility ensures the system can be precisely tailored to match the specific requirements of each protected area, from simple single-zone applications to complex multi-zone scenarios requiring sophisticated release logic.

Sigma XT panels are engineered for both robustness and installation efficiency, featuring all electronics mounted on a single, easily removable steel plate. This design philosophy ensures reliable operation in demanding environments whilst significantly reducing installation time and complexity. The panel’s comprehensive feature set includes configurable delays, countdown timers, and extensive status indication capabilities, making it the preferred choice for professional fire protection installers worldwide.

Features

  • Three detection zones supporting up to 32 devices per zone
  • Flexible zone configuration – any single zone or combination can trigger release
  • Configurable extinguishant delays up to 60 seconds in 5-second steps
  • Configurable extinguishant duration up to 5 minutes in 5-second steps
  • Visual countdown timer showing time remaining until release
  • Built-in extract fan control with dedicated relay output
  • Support for up to seven four-wire status indicators
  • Zero time delay option upon manual release
  • Compatible with intrinsically safe barriers
  • Non-latching zone input option for aspirating equipment integration
  • Configurable first stage sounder delays
  • Configurable detection delays for each zone
  • Two-wire RS485 connection for status units
  • Multiple relay outputs for fire, fault, and stage indications
  • 230V AC mains supply with battery backup capability
  • 3 Amp power supply including battery charge capability
  • Temperature compensated battery charging
  • Comprehensive programmable functions with multi-level access
  • Single removable steel plate electronics mounting
  • Robust 1.2mm mild sheet steel construction

FAQ

How many detection zones does the Sigma XT support?

The Sigma XT features 3 detection zones as standard, each capable of supporting up to 32 devices depending on the detector type. Any single zone or any combination of zones can be configured to trigger extinguishant release.

What extinguishant delay options are available?

The system offers configurable extinguishant delays from 0 to 60 seconds in 5-second steps, with a zero time delay option specifically available for manual release activation. The extinguishant duration can be set from 60 to 300 seconds, also in 5-second increments.

Can the system integrate with aspirating smoke detection equipment?

Yes, the Sigma XT includes a non-latching zone input option specifically designed to receive signals from other systems such as aspirating equipment, providing seamless integration with advanced detection technologies.

How many remote status indicators can be connected?

The system supports up to seven four-wire status indicators connected via a two-wire RS485 communication link, allowing comprehensive remote monitoring and control capabilities throughout the protected facility.

Is the system compatible with intrinsically safe environments?

Yes, the Sigma XT is compatible with intrinsically safe barriers and can be configured for use in hazardous environments where spark prevention is critical. This feature can be enabled through the programmable functions menu.

What power supply and battery backup is provided?

The panel operates on 230V AC mains supply with a 3 Amp power supply rating. Battery backup is provided by two 12V 7Ah sealed lead acid batteries connected in series, with temperature compensated charging at 27.6V DC nominal.

Specifications

  • Product Code: K11031M2
  • Construction: 1.2mm mild sheet steel
  • Dimensions: 385 x 310 x 90mm
  • IP Rating: IP30
  • Finish: Epoxy powder coated
  • Colour Lid & Box: BS 00 A 05 grey – fine texture
  • Colour Control Panel & Labels: RAL 7047 light grey – satin
  • Weight: 6kg
  • Mains Supply: 230V AC +10%/-15% (100 Watts maximum)
  • Mains Supply Fuse: 1.6 Amp (F1.6A L250V)
  • Power Supply Rating: 3 Amps total including battery charge 28V +/- 2V
  • Maximum Ripple Current: 450 millivolts
  • Battery Type: Two 12 Volt 7Ah sealed lead acid in series
  • Battery Charge Voltage: 27.6VDC nominal (temperature compensated)
  • Battery Charge Current: 0.7A maximum
  • Battery Fuse: 20mm, 3.15A glass
  • Maximum Current Draw From Batteries: 3 Amps
  • Quiescent Current In Mains Fail: 0.095A
  • R0V Output: Fused at 500mA with electronic fuse
  • Sounder Outputs: 24V Fused at 500mA with electronic fuse
  • Relay Contact Rating: 30VDC 1A maximum (all relays)
  • Zone Quiescent Current: 2mA maximum
  • Terminal Capacity: 0.5mm² to 2.5mm² solid or stranded wire
  • Number Of Detectors Per Zone: Dependent on type (maximum 32)
  • Number Of Sounders Per Circuit: Dependent on type (max. 0.5A per circuit)
  • Detection Circuit End Of Line: 6K8 5% ½ Watt resistor
  • Monitored Input End Of Line: 6K8 5% ½ Watt resistor
  • Sounder Circuit End Of Line: 10K 5% ¼ Watt resistor
  • Extinguishant Output EOL: 1N4004 Diode
  • Number Of Detection Circuits: 3
  • Number Of Sounder Circuits: 2 x 1st Stage, 1 x 2nd Stage
  • Extinguishant Release Output: Fused at 1 Amp
  • Extinguishant Release Delay: Adjustable 0 to 60 seconds (in 5 second steps)
  • Extinguishant Release Duration: Adjustable 60 to 300 seconds (in 5 second steps)
  • Status Unit Connection: Two wire RS485 connection
  • Status Unit Power Output: Fused at 500mA with electronic fuse
  • Approvals: EN12094-1, EN54-2 and EN54-4
  • UL And FM Approved Version: Also available