SMS SenTRI Single Output Module
£50.90 (inc VAT: £61.08)
Summary
The SenTRI Single Output Module (SEN-INT-OUTPUT) is a compact and versatile addressable interface unit designed for seamless integration within the SMS SenTRI fire detection system. This sophisticated module provides a single, independently controllable output for activating external devices during fire events, ensuring critical building systems respond appropriately to emergency situations.
The module’s main features include a volt-free changeover relay, allowing it to interface with a wide range of third-party equipment such as automatic door closers, smoke vents, fire shutters and other building management systems. The built-in short-circuit isolator enhances system resilience and simplifies fault finding on the SenTRI loop, ensuring continued operation even if individual devices experience faults. Its compact design makes installation straightforward whilst maintaining professional standards required for commercial fire safety systems.
Features
- Single independently controllable output
- Volt-free changeover relay operation
- Built-in short-circuit isolator
- Addressable for precise system integration
- Compact design for easy installation
- Compatible with automatic door closers
- Smoke vent control capability
- Fire shutter integration
- Building management system interface
- Enhanced system resilience
- Simplified fault finding
- Loop powered operation
- Load factor of 2 per module
- Maximum 200 modules per loop
- Individual sectoring capability (maximum 8)
- Wide operating temperature range
- Multiple enclosure options available
- EN54-17 and EN54-18 compliance
- LPCB approved design
- SMS SenTRI system compatibility
FAQs
What external devices can the SEN-INT-OUTPUT control?
The module can interface with a wide range of third-party equipment including automatic door closers, smoke vents, fire shutters, and other building management systems through its volt-free changeover relay.
How many SEN-INT-OUTPUT modules can I install per loop?
You can install a maximum of 200 modules per loop, with each module having a load factor of 2. However, only 8 modules can be individually sectored per loop.
What panel compatibility requirements does the module have?
The SEN-INT-OUTPUT is compatible with Loop version 4.35 and Main Control Card version 4.37 or higher, ensuring seamless integration with current SenTRI systems.
What protection does the short-circuit isolator provide?
The built-in short-circuit isolator enhances system resilience by protecting the loop from faults and simplifies fault finding, ensuring continued operation of other devices on the loop even if one module experiences issues.
What enclosure options are available for the module?
The module can be housed in plastic box SEN-490 (IP31 protection) or metal box SEN-492 (IP40 estimated protection), providing flexibility for different installation environments.
Specifications
- Product Code : SEN-INT-OUTPUT
- Description : SenTRI Single Output Module
- Output Configuration : Single independently controllable output
- Relay Type : Volt-free changeover relay
- Isolation : Built-in short-circuit isolator
- Weight : 100g
- Operating Temperature : -10°C to +60°C
- Panel Compatibility : Loop V4.35 and Main Control Card V4.37
- Load Factor : 2 per module
- Maximum Per Loop : 200 modules
- Individual Sectoring : Maximum 8 per loop
- Ingress Protection : IP31 (plastic box SEN-490), IP40 estimated (metal box SEN-492)
- Standards : EN54-17, EN54-18
- Approvals : LPCB Approved
- System Compatibility : SMS SenTRI fire detection system
- Installation Type : Addressable interface unit
- Application : External device control, building management integration
- Enclosure Options : SEN-490 plastic box or SEN-492 metal box
Downloads
- Brochure (Adobe PDF)
Additional information
| Weight | 0.10 kg |
|---|---|
| System Type | |
| Device Type | |
| Protocol |