Quantec-Pro Corridor Display
£171.44 (inc VAT: £205.73)
Summary
The Quantec-Pro Corridor Display (QP908C) is a purpose-built call indication device designed for healthcare and care facility environments. Installed in corridors, staff rooms and nursing stations, this display provides clear and immediate visibility of incoming calls from a Quantec-Pro call system, ensuring staff can respond quickly to resident or patient needs.
Featuring a high-contrast OLED display, the unit presents call information with exceptional clarity, showing call type, location, and caller identification. The intelligent priority system ensures the most urgent calls are displayed first, with a counter showing how many calls are waiting. Both visual and audible alerts intensify according to call urgency, helping staff prioritise their response effectively.
The device incorporates an onboard sounder capable of generating multiple standard and HTM-specific tones, with adjustable volume controls and the option to connect an external sounder for enhanced coverage. Three intuitive buttons allow staff to accept calls and scroll through current events, whilst adjustable contrast ensures optimal visibility in varying lighting conditions. With its ergonomic design and surface-mountable format, the Quantec-Pro Corridor Display integrates seamlessly into any care environment.
Features
- 2-line x 20-character backlit OLED display with 4 suffix indicators
- Support for place names up to 24 characters
- Displays call type, call location and caller ID or name
- Priority-based call display with waiting call counter
- Flash and sounder rates intensify to reflect call urgency
- Onboard sounder with multiple standard and HTM-specific tones
- External sounder connection capability
- Three control buttons: Accept, Scroll Up, Scroll Down
- Adjustable display contrast control
- Adjustable volume control
- Internal/external beeper enable option
- Powered from Quantec Controller/Network (24V DC nominal)
- Surface mounting installation
- Ergonomic plastic construction with IP41 rating
- Compatible with Quantec Surveyor2 App for smartphone and tablet integration
FAQ
What is the Quantec-Pro Corridor Display used for?
The Quantec-Pro Corridor Display is designed to indicate incoming calls from a Quantec-Pro call system in corridors, staff rooms and nursing stations within healthcare and care facilities. It provides visual and audible alerts to ensure staff are immediately aware of calls requiring attention.
How does the priority system work?
The display automatically shows the highest priority calls first, with a message indicating how many calls are waiting. Flash and sounder rates intensify to reflect the urgency of incoming calls, helping staff prioritise their response to the most critical situations.
Can the display show caller information?
Yes, depending on the device used to make the call, the display can show the User ID or name of the person calling, along with the call type and call location. This provides staff with essential context before responding to a call.
What tones are available on the sounder?
The onboard sounder can generate multiple standard tones as well as HTM-specific tones, ensuring compliance with healthcare guidance. The volume is adjustable, and there is an option to enable either the internal beeper or an external sounder.
How is the display powered?
The Quantec-Pro Corridor Display is powered directly from the Quantec Controller/Network at a nominal 24V DC, with a quiescent current of just 4.4mA. This eliminates the need for separate power supplies and simplifies installation.
Can I connect an external sounder?
Yes, the unit includes an external sounder connection (current sink to the NET- line rated at 30V, 30mA, 300mW dissipation maximum), allowing you to extend audible coverage to additional areas if required.
What are the physical dimensions?
The display measures 154mm wide x 125mm high x 34mm deep and weighs 200g. It is designed for surface mounting and features an ergonomic design suitable for installation in various locations.
Is the display suitable for all environments?
The Quantec-Pro Corridor Display has an IP41 rating and operates in temperatures ranging from -5°C to +40°C with maximum relative humidity of 95%. This makes it suitable for most indoor care facility environments.
Specifications
- Part Number: QP908C
- Power Requirements: Nominal 24V DC (from Quantec Controller/Network)
- Quiescent Current: 4.4mA
- Display Type: 2 line x 20 characters plus 4 suffix backlit OLED display
- Place Name Support: Up to 24 characters
- Controls: Accept (A); Scroll Up; Scroll Down; Adjust contrast; Adjust volume; Enable internal/external beeper
- Connections: Net +, Net –
- Expansion Connections: External sounder connection (current sink to the NET- line rated at 30V, 30mA, 300mW dissipation max.)
- Onboard Sounder: Yes
- Onboard Infrared Receiver: No
- Product Dimensions: 154mm W x 125mm H x 34mm D
- Mounting Type: Surface mounting
- Construction & Finish: Plastic
- IP Rating: IP41
- Weight: 200g
- Operating Temperature: -5°C to +40°C
- Maximum Relative Humidity: 95%
Downloads
- Datasheet (Abobe PDF)
Additional information
| Device Type | |
|---|---|
| System Type |