Apollo SA5900-908 Addressable Manual Call Point | Integral Isolator
£31.02 (inc VAT: £37.22)
Key features
- XP95, Discovery and CoreProtocol compatibility
- Front reset with the supplied key
- Removable terminal block for installation
Downloads
Summary
This is the red Apollo SA5900-908 Intelligent Manual Call Point, a resettable device for indoor XP95, Discovery and CoreProtocol systems. It provides manual alarm activation on a compatible Apollo-protocol loop, with an integral short-circuit isolator and front reset using the supplied key.
View full overview Show less
You can wire the installation cabling into the removable terminal block and choose semi-flush or surface mounting. Apollo’s component list includes a backbox, mounting bracket, reset key and continuity link for cable insulation testing before commissioning.
Pressing the resettable element displays yellow and black indication bars, with a red alarm indicator controlled by the panel. Use the installation guide in Downloads for addressing, mounting, testing and commissioning.
Features
- Reset after testing - the resettable operating element returns to service using the supplied front reset key
- Wire before fitting - installation cabling terminates in a removable connector block at the rear of the call point
- Choose the mounting arrangement - suitable for semi-flush or surface mounting, with a backbox in the manufacturer’s component list
- Check cable continuity - the supplied continuity link supports cable insulation testing before commissioning
- Identify activation - yellow and black indication bars show the operated element, with a panel-controlled red alarm indicator
- Limit a loop short circuit - an integral isolator disconnects the affected loop section; performance depends on the loop design and fault location
FAQ
Apollo lists all three protocols for this call point. Match it to compatible Apollo-protocol control equipment and the panel’s approved device configuration; a protocol name alone is not a guarantee for every control panel. Apollo’s installation guide identifies SA5900-908 as an indoor call point. Its operating temperature range and IP44 rating do not change that application classification, so select a purpose-designed outdoor model where the installation requires one. The address is set during commissioning using the dual-in-line (DIL) switch. Apollo’s installation guide specifies segment 8 in position 0 for XP95 or Discovery operation; use the guide’s addressing diagram and the panel’s commissioning instructions for the required address and protocol setup. Use the supplied reset key at the front reset point and turn clockwise until the positive click confirms that the element has reset. The red alarm indication is controlled by the panel, so follow the panel’s procedures to restore the complete system after the device has been physically reset. Apollo’s component list includes a backbox, mounting bracket, reset key and continuity link, and the device supports semi-flush or surface mounting. A transparent hinged cover is a separate accessory: 44251-189 individually or 44251-175 in packs of 10. The guide identifies the wall-fixing screws separately as not supplied. Red indicates alarm under control-panel control, flashing yellow indicates a fault, and solid yellow indicates that the short-circuit isolator has operated. The installation guide specifies flashing green polling indication for Discovery and Soteria operation. If an unexpected indication remains, check the panel event information and the installation guide before investigating the device and loop wiring.Will SA5900-908 work on XP95, Discovery or CoreProtocol systems?
Can this red call point be installed outdoors?
How is the call point address set?
How do I reset it after a test or activation?
Does it include a backbox and a hinged cover?
What do the indicator colours mean?
Specifications
| Model | SA5900-908; Apollo part number SA5900-908APO |
|---|---|
| Colour | Red |
| Device Type | Type A addressable manual call point |
| Operating Element | Resettable, single-action |
| Environment | Indoor |
| Protocol Compatibility | XP95, Discovery and CoreProtocol; use with compatible Apollo-protocol control equipment |
| Short-Circuit Isolator | Integral |
| Supply Voltage | 17-28V DC in Apollo datasheet PP2526/2026 Issue 6 |
| Modulation Voltage | 5-13V peak to peak |
| Power-Up Surge Current | 1mA; 1 second typical, maximum current figure at 24V DC |
| Quiescent Current | 100µA maximum at 24V DC |
| Alarm Current | 4mA maximum at 24V DC with alarm light-emitting diode (LED) on |
| Typical Data Conditions | 24V, 25°C and 50% relative humidity unless otherwise stated in Apollo’s datasheet |
| Operating Temperature | -40°C to +70°C; indoor application |
| Humidity | 0-95% relative humidity, without condensation or icing |
| IP Rating | IP44; indoor model |
| Dimensions | 90mm high x 90mm wide x 63mm deep |
| Weight | 180g |
| Housing Material | Red flame-retardant polycarbonate |
| Mounting | Semi-flush or surface |
| Address Setting | Dual-in-line (DIL) switch; segment 8 set to 0 for XP95 or Discovery operation |
| Reset Method | Supplied key operated at the front reset point |
| LED Viewing Angle | 170° |
| Status Indications | Red: alarm under panel control; flashing yellow: fault; solid yellow: isolator operated. Flashing green polling indication applies to Discovery and Soteria operation in the installation guide |
| Supplied Components | Head unit, connector block, two fixing screws, mounting bracket, earth continuity terminal, backbox, reset key and continuity link, as listed in Apollo’s installation guide |
| Optional Hinged Cover | 44251-189 individually or 44251-175 in packs of 10; separate accessory |
| Standards | EN 54-11:2001 and EN 54-17:2005, as listed in Apollo’s product datasheet |
Downloads
- Datasheet (Adobe PDF)
- Installation Guide (Adobe PDF)
Additional information
| Weight | 1 kg |
|---|---|
| Environment | |
| Hazardous Applications | |
| Marine Applications | |
| Short Circuit Isolator | |
| System Type | |
| Protocol | |
| Device Type |