Shopping Basket

0 Items

Subtotal £0.00

Fire Alarm Panels

Showing 193–201 of 201 results

  • SmartConnect Multi-Loop Multi-Input Module

    SmartConnect Multi-Loop Multi-Input Module

    • Designed to EN54 Part 2
    • Each input is monitored for open & short circuits
    • Extensive front unit status indications (See Datasheet)
    • Quick and easy to install by plugging the RJ45 cable into the module and control panel (cable supplied with Unit)
    • Each input can be configured as either Alarm or Supervisory

    Low Stock

    £115.94 (inc VAT: £139.13)
    SKU: SCM-MIM
    Add to basket
  • SmartConnect Multi-Loop Multi-Relay Output Module

    SmartConnect Multi-Loop Multi-Relay Output Module

    • Designed to EN54 Part 2
    • 3 x Form C relay outputs
    • Each relay can be programmed to activate on Alarm, Technical Alarm, or Fault.
    • Extensive front unit indications (see datasheet)
    • Quick and easy to install by plugging the RJ45 cable into the module and control panel (cable supplied with Unit)

    Low Stock

    £102.81 (inc VAT: £123.37)
    SKU: SCM-RM
    Add to basket
  • SmartConnect Multi-Loop Repeater

    SmartConnect Multi-Loop Repeater

    • 4.3” colour touch screen display
    • 8032 event log entries
    • Up to 64 panel peer-to-peer network
    • 13 status LED indicators
    • 5 function button controls
    • Fully functioning repeater provides the ability to program a networked Smart Multi-loop control panel from the front screen
    • Accommodates wiring lengths up to 1000 metres from the control panel for added design and install flexibility
    • Network can we wired in either a bus or a ring topology if a redundant path is required
    • 8 password protected access accounts available (1 admin level, 7 user level)
    • Uncluttered and intuitive interface allows alarms, tech alarms, and fault events to be easily viewed
    • Low power consumption
    • Small enclosure

    Low Stock

    £424.38 (inc VAT: £509.26)
    SKU: SMART/REP
    Add to basket
  • SmartConnect Multi-Loop RS485 Network Module

    SmartConnect Multi-Loop RS485 Network Module

    • Designed to EN54 requirements
    • Peer-to-peer networking
    • Comprehensive cross network cause & effects
    • Remote programming over the network
    • The network can be configured with either a ring or bus topology
    • Extensive front unit status indications (See datasheet)
    • Quick and easy to install by plugging the RJ45 cable into the module and control panel (Cable supplied with unit)

    Low Stock

    £205.63 (inc VAT: £246.76)
    SKU: SCM-NM
    Add to basket
  • SmartConnect Multi-Loop TCP/IP Module

    SmartConnect Multi-Loop TCP/IP Module

    • Designed to EN54 requirements
    • TCP-IP output via RJ45
    • Zeta Remote monitoring via a desktop PC or smartphone via the cloud
    • Remote control via the cloud
    • Responsive web interface
    • “Heartbeat LED” that shows communication between the module and the motherboard
    • Extensive front unit indications
    • Quick and simple to install

    Low Stock

    £219.63 (inc VAT: £263.56)
    SKU: SCM-LAN
    Add to basket
  • Sounder Active EOL For Advanced MxPro 5

    Sounder Active EOL For Advanced MxPro 5

    • For use with EN54-13 Compliance.
    • Supports device removal.
    • For use with all MxPro 5 series control panels.

    In Stock

    £16.74 (inc VAT: £20.09)
    SKU: MXP-505
    Add to basket
  • Spare Paper Roll for Advanced Printer

    Low Stock

    £10.54 (inc VAT: £12.65)
    SKU: MXS-509
    Add to basket
  • TwinflexPro2 505-0007 Conventional Expansion Card

    TwinflexPro2 505-0007 Conventional Expansion Card

    • Expand TwinflePro2 panel with 4 conventional zones.
    • Compatible with Apollo, Hochiki, Nittan or System Sensor conventional detectors.
    • Compatible with TwinflexPro2 4 zone panel only.

    Low Stock

    £124.39 (inc VAT: £149.27)
    SKU: 505-0007
    Add to basket
  • Ziton Conventional Fire Panel Supervised or Unsupervised Relay Board

    Ziton Conventional Fire Panel Supervised or Unsupervised Relay Board

    • Bus Type Easy Cable Free Installation
    • Output Delay per Output
    • "AND" "OR" Programming Functionality
    • Powered from Panel Bus
    Select options This product has multiple variants. The options may be chosen on the product page

The fire alarm panel is the central element of any fire alarm system. All devices (detectors, call points, sounders, etc.) are connected to the fire panel, which typically provides power to them and information is relayed back and forth to determine whether there is a fire and if so activate an appropriate warning.

If you’re not too sure which fire alarm panels are suitable for your needs, there are several factors that should be considered. Any fire alarm system that has been designed to the British standard BS 5839 will divide the property up into zones (physical areas which can be identified by a zone number used to locate the fire). Every fire alarm panel will have a zone capacity and this must be sufficient to accommodate however many zones your system needs. Secondly do you know what type of system you need to install? Broadly speaking there are 3 types of fire panel; conventional, 2 wire or addressable and each is summarised as follows; Conventional fire alarm panels are considered the most basic and economical in terms of the equipment itself. Detectors and call points for each zone are connected in series, which ends at the last device and terminates at the panel (radial circuit). Warning devices (sounders and flashers) must be connected to a separate sounder circuit. In the event of a fire the panel will simply show which zone this has occurred in (it is worth considering that a single zone may contain up to 32 detectors). 2 wire fire alarm panels can be thought of as an evolution of conventional panels. To overcome the additional cabling needed for the separate sounder circuit, 2 wire panels allow any type of device (detectors, call points or sounders) to be connected in series on the same wire. However, alarm indication is still limited to only showing which zone the fire is in. Addressable fire alarm panels (sometimes referred to as intelligent fire alarm panels) are the most advanced type of fire panel. All devices for every zone are connected to the same wire which is looped from the panel to each device in series before returning back to the panel. Through a system of addressing, addressable panels can identify each individual device to assign them into a zone. In alarm condition the panel will not only show the zone number but also a text description (for instance “bedroom 2”) of the device. Further benefits are gained from this loop wiring including system integrity if there is a cable break. Finally some other considerations in your fire alarm panels selection are;

  • Do you need to interface with auxiliary equipment such as door holders? Most panels have an onboard fire relay and others provide interfaces that can be installed with field devices.
  • Do you need to remotely monitor the fire panel? Some panels can interface with a number of communicators such as IP (over the internet), GSM or telephone and the status of the panel will be relayed to a remote location.

If you need assistance choosing the right fire alarm panel feel free to contact us on 01792 983 170.

Trade
Account
Enquiry?