Kentec Sigma CP Sav-Wire Two-Wire Fire Alarm Panel

SKU: 530b0f903d59
SKU: 530b0f903d59 Category: Brand:

Summary

The Kentec Sigma CP Sav-Wire Two-Wire Fire Alarm Panel is a conventional fire alarm control panel engineered for demanding fire detection and alarm system applications. Designed with ease of installation in mind, the two-wire configuration significantly reduces wiring complexity, making it an ideal choice for new installations and panel replacements on existing systems alike.

Available in 2, 4 and 8 zone configurations, the Sigma CP two-wire range offers flexibility to suit a wide variety of premises and project sizes. The panel is compatible with two-wire detector bases from leading manufacturers Apollo and Hochiki, as well as most standard conventional detectors, call points and sounders, ensuring broad compatibility across installations.

Fully certified to BS EN54-2 and BS EN54-4, and compatible with BS5839: Part 1: 2017 installations, the Sigma CP delivers reliable performance and regulatory compliance. Extensive programmable configuration options — stored in non-volatile memory — are accessible via an intuitive user interface, allowing engineers to tailor the system quickly and efficiently on site.

Key Features

  • Fully certified to BS EN54-2 and BS EN54-4
  • 2-wire in 2, 4 or 8 zones
  • Compatible for use on BS5839: Part 1: 2002 installations
  • 2-wire repeaters and ancillary boards
  • Fully programmable using simple menu options
  • Adjustable sounder delay time
  • Sounder configuration options
  • Zonal sounder delay detectors only
  • Zonal sounder delay call points only
  • Coincidence input selection
  • I.S Barrier selection by zone
  • Short circuit fire by zone
  • Non latching zones Silent zones
  • Zone input delay
  • General panel configuration
  • Simple, single board construction
  • Installer friendly
  • Compatible with wide range of detection devices
  • Two monitored sounder outputs 3 Amp power supply
  • Auxiliary power output

Specifications

  • Construction: 1.2mm mild sheet steel
  • IP Rating: IP30
  • Finish: Epoxy powder coated
  • Colour (Lid And Box): BS 00 A 05 grey – fine texture
  • Colour (Control Panel And Labels): RAL 7047 light grey – satin
  • Weight: 6kg
  • Dimensions: 385 x 310 x 90mm
  • Supply Voltage: 230V AC (+10%/-15%)
  • Mains Supply Fuse: 1.6 Amp 250V
  • Power Supply DC Rating: 24V 3 Amps
  • Maximum Battery Size: 7Ah 12V (2 per panel)
  • Fault Contract Rating: 30V DC 1 Amp
  • Local Fire Contract Rating: 30V DC 1 Amp
  • Fire Contract Rating: 30V DC 1 Amp
  • Sounder Output Rating: 0.5A per output (max 1.6A over all outputs)
  • Detection Zone Current: 1.6 milliamps
  • Detection Zone EOL Resistor: 6k8 5%
  • Sounder Output EOL Resistor: 10k 5%
  • Cable Capacity: 2.5mm² per terminal
  • Operating Temperature: -5°C to +40°C
  • Operating Humidity: <95% (non condensing)
  • Alarm Current (2 Zone): 0.15 Amps
  • Alarm Current (4 Zone): 0.3 Amps
  • Alarm Current (8 Zone): 0.63 Amps
  • Standby Current (2 Zone): 0.065 Amps
  • Standby Current (4 Zone): 0.075 Amps
  • Standby Current (8 Zone): 0.093 Amps
  • Certifications: BS EN54-2, BS EN54-4

Features

  • Two-wire panel design reduces installation time and wiring costs
  • Available in 2, 4 or 8 detection zones
  • Compatible with BS5839: Part 1: 2017 installations
  • Fully certified to BS EN54-2 and BS EN54-4
  • Compatible with Apollo and Hochiki two-wire detector bases
  • Compatible with a wide range of conventional detectors, call points and sounders
  • Two monitored sounder outputs
  • 3 Amp, 24V DC power supply
  • Auxiliary power output
  • Simple single board construction
  • Fully programmable via intuitive menu-driven interface
  • Configuration stored in non-volatile memory
  • Adjustable sounder delay time
  • Zonal sounder delay for detectors only or call points only
  • Coincidence input selection
  • IS barrier selection by zone
  • Short circuit fire by zone
  • Non-latching zones
  • Silent zones
  • Zone input delay
  • Maximum battery size 7Ah 12V (2 per panel)
  • Two-wire repeaters and ancillary boards available

FAQ

What is the difference between the two-wire and four-wire Sigma CP panels?

The two-wire (T-prefix) Sigma CP panels use a two-wire detection circuit, which simplifies wiring and reduces installation time and cable costs compared to standard four-wire panels. The two-wire versions are compatible with Apollo and Hochiki two-wire detector bases, making them particularly suited to installations where wiring efficiency is a priority.

How many detection zones are available?

The Sigma CP two-wire range is available in 2 zone (T11020M2), 4 zone (T11040M2) and 8 zone (T11080M2) variants, allowing you to select the appropriate panel for the size and complexity of your installation.

Is the Sigma CP two-wire panel certified to the relevant fire alarm standards?

Yes. All Sigma CP panels are fully certified to BS EN54-2 (Fire detection and fire alarm systems — Control and indicating equipment) and BS EN54-4 (Power supply equipment), and are compatible for use on BS5839: Part 1: 2017 installations.

What detectors and devices are compatible with the Sigma CP two-wire panel?

The Sigma CP two-wire panel is compatible with two-wire detector bases from Apollo and Hochiki, as well as most standard conventional detectors, call points and sounders. This broad compatibility makes it suitable for a wide range of fire detection system designs.

What are the alarm current ratings for the two-wire panels?

The alarm current ratings for the two-wire panels are: 0.15 Amps for the 2 zone model (T11020M2), 0.3 Amps for the 4 zone model (T11040M2), and 0.63 Amps for the 8 zone model (T11080M2).

What battery backup does the Sigma CP support?

The Sigma CP panel supports a maximum battery size of 7Ah 12V, with two batteries per panel, providing standby power in the event of a mains supply failure in accordance with fire alarm system requirements.