Apollo XP95 Addressable Open-Area VID
- Available in red, amber, and clear lens with red flash
- Digital communication compatible with XP95, Discovery, and CoreProtocol
- Designed for indoor use with IP23D rating
-

Apollo Marine Isolating Base
- Up to 20 detectors or their equivalent load, may be installed between isolating bases
- High-brightness LED
- Detects wiring short-circuits
- Minimises disruption from short-circuits
-

Apollo MiniDisc Remote Indicator
- Small and discrete remote indicator
- Compatable with with Apollo XP95, AlarmSense or Series 65 detectors
-

Apollo New Style Call Point Keys – Pack of 10
- Apollo New Style Call Point Key
- Pack of 10
- Allow Users to test Call Points for Correct Operation
-

Apollo ORB-BA-10008-APO Series 65 to Orbis Base Adapter
- Enables an existing range to be updated with ease.
- Eliminates the need for re-wiring.
-

Apollo Orbis Conventional Optical Smoke Detector
- Improved sensitivity to black smoke
- Compensation for build-up of dirt
- Extra confirmation of smoke before an alarm signal is given
-

Apollo Orbis Conventional Optical Smoke Detector, Non-Latching
- Improved sensitivity to black smoke
- Compensation for build-up of dirt
- Extra confirmation of smoke before an alarm signal is given
-

Apollo Orbis Duct Detector
Key Features
- For use with Series 65 or Orbis detectors.
- Operates in air speeds of 0.5m/s to 20m/s.
- Transparent cover to view detector head LED.
- Integral smoke test port.
- Volt-free contacts.
-

-

Apollo Orbis Timesaver Diode Detector
- Designed for seamless integration with Orbis systems
- Simplifies installation and enhances detector performance
- Ensures reliability and compatibility with various fire alarms
-

Apollo Orbis TimeSaver Sav-Wire Base
- Grouped terminals to make wiring easy
- Two fixing centres
- LED alignment mark
- Cable stripping guide
- Detector locking mechanism
- Is used in 'Sav-Wire' systems
-

Apollo Intelligent Test Set
- Seven-inch LCD touch screen display for intuitive operation
- Compatible with XP95, Discovery and CoreProtocol ranges
- Lithium-ion battery powered with USB connectivity
-

Apollo SC2900-001 Conventional Manual Call Point
- Resettable operating element.
- Easy access, front reset mechanism.
- Ergonomic reset key.
- EN54-11 certified.
- 170° viewable LED.
- Suitable for flush or surface mouting.
- Optional hinged cover.
-

Apollo Series 65 12V DC Relay Base
- Detector locking mechanism
- One way fit
- Easy to wire
- Contains an earth connector
- Can be used in fire and security systems
-

Apollo Series 65 Diode Base
- Detector locking mechanism
- Easy to wire
- Contains an earth connector
- Terminal for remote indicator
-

Apollo Series 65 End-of-Line Relay Base
- Detector locking mechanism
- One way fit
- Easy to wire
- Contains an earth connector
-

Apollo Series 65 or XP95 Base Cover
- Protects base when the detector is not in place.
- Aesthetically pleasing.
£3.30 -

Apollo Series 65 Sav-wire Base
- Allows Series 65 conventional detection to work on Sav-Wire panels
- Detector locking mechanism
- Contains an earth connector
- Easy to wire
-

Apollo Series 65 Standard Base
- Detector locking mechanism
- Easy to wire
- Contains an earth connector
- Terminal for remote indicator
-

Apollo Series 65 Standard Relay Base
- Detector locking mechanism
- One way fit
- Easy to wire
- Contains an earth connector
-

Apollo Stainless Steel Adjustable Mounting Bracket
- Base mounted flame detector bracket
-

Apollo Weatherproof Multi-Tone Open-Area Sounder Visual Indicator with Isolator (Red)
- Choice of tones on standard device: Apollo, Slow Whoop, and DIN.
- IP66 rated.
- Two Volume settings 92dB(A) and 100dB(A).
- Synchronisation of 'alert' and 'evacuate' tones.
- Individual and group addressing.
- Built in isolator.
-

Apollo XP95 3 Channel Input/Output Unit
- Uses a single address.
- Allows independent monitoring of input channels.
- Allows independent control of output relays.
-

Apollo XP95 Addressable Output Unit
- The Output Unit provides a voltage free single pole, changeover relay output.
- It is a simplified version of the Input/Output Unit without circuitry for monitoring inputs.
-

Apollo XP95 Sounder VAD Base
- EN54-23 compliant VAD with built-in isolator
- Two adjustable volume ranges 55–91dB(A)
- Unique acoustic and VAD self-test capability
-

Apollo XP95 Ancillary Base Sounder
- For use on an XP95/Discovery systems.
- Sound output of 85dB(A) at 1 metre.
- Current consumption of only 3mA.
- Loop-powered.
- Responds to signals from the associated detector – does not have an address of its own.
-

Apollo XP95 Blanking Cap For Base Sounders
- Blanking cap for XP95 sounder or combined sounder & flasher bases.
- Suitable for applications where no detector is required.
- Available in either red or white.
-

Apollo XP95 Dual Channel DIN-Rail Isolator
- Two independent isolators in one DIN-rail housing
- Loop-powered with visual LED fault indication
- Supports up to 20 XP95 detectors between isolators
-

Apollo XP95 DIN-Rail Mains Switching Input / Output Unit
- It can report fault, switch open and switch closed levels
- Three visible LEDs
- Capable of switching up to 8A at 250V AC
- Fits a standard 35mm DIN-Rail
-

Apollo XP95 DIN-Rail Sounder Controller (5 Amperes)
- Allows sounders to be operated continuously or be pulsed, 1 second on, 1 second off
- May be synchronised with loop sounders
- An opto-coupled input is provided to monitor the state of the external power supply
- Features group addressing
- Will accept a load of up to 5A
-

Apollo XP95 High Temperature Heat Detector
- Ideal in environments that are dirty or smoky under natural conditions
- Well suited for warehouses, loading bays and car-parks
- Unaffected by wind or atmospheric pressure
-

Apollo XP95 I.S MEDC Manual Call Point
- Robust design
- Waterproof
- Reports an alarm in under 0.2 seconds
-

Apollo XP95 I.S. Manual Call Point
- Intrinsically safe for use in hazardous areas
- IP67 rated for indoor and outdoor applications
- Rapid alarm reporting in less than 0.2 seconds
-

Apollo XP95 I.S. Mounting Base
- Universal XPERT card addressing
- One-way fit design
- Only accepts intrinsically safe detectors
-

Apollo XP95 Input/Output Unit With Isolator
The Apollo XP95 Input/Output Unit provides a voltage-free, double pole changeover (DPCO) relay output, a single monitored switch input and an unmonitored, non-polarised opto-coupled input.
-

Apollo XP95 Intelligent Deep Base
Compatible with all Apollo XP95 detectors, the Intelligent Deep Base has extra depth to allow cable-insertion through the side of the base.
-

Apollo XP95 Intelligent Heater Base
The Intelligent Heater Base protects your Apollo XP95 detectors from environmental factors like icing and condensation.
-

Apollo XP95 Intelligent Isolator
- Patented short-circuit detection technology
- Automatic restoration when fault cleared
- Compatible with XP95, Discovery and CoreProtocol systems
-

Apollo XP95 Intelligent Isolator Base
This base is required to add the Apollo XP95 Intelligent Isolator to your fire alarm system.
-

Apollo XP95 Intelligent Mounting Base in White or Black
- XPERT Addressing.
- One way fit of detector.
- Locking feature to prevent unauthorised detector removal.
-

Apollo XP95 Intelligent Twin Switch Monitor
- Twin switch montor for Apollo intelligent systems.
- Improved design for ease of wiring meaning faster installation.
- Contains controllable isolator.
- Address range 1 - 254.
- Five pre-configured modes, including compatibility mode from XP95/Discovery to CoreProtocol systems.
-

Apollo XP95 Isolating Base
The XP95 Isolating Base isolates short circuits in the addressable loop while allowing the associated detector to remain active.
-

Apollo XP95 Loop Powered VAD, White Body, White Flash, Ceiling Category
- Uses high intensity LED.
- EN 54-23 Compliant Category C VAD.
- Flash rate 0.5Hz.
- Fault signal if LED check failed.
-

Apollo XP95 Loop-Powered Visual Indicator Base with Isolator
- Visual indicator flash rate of once per second
- Synchronisation of visual indicator flash
- Individual and group addressing
- Unique visual indicator self-test
- Loop-powered
- Built-in Isolator
-

Apollo XP95 Mini Switch Monitor
Enter a brief description of your product here. This description will be displayed on product list pages.
-

Apollo XP95 Multi-tone Open Area Indoor Sounder
- Two volume settings 92dB(A) and 100dB(A).
- Synchronisation of ‘alert’ and ‘evacuate’ tones.
- Individual & group addressing.
- Three tones on standard devices; Apollo, slow whoop and DIN – all of which comply with EN54–3:2001.
-

Apollo XP95 Multisensor Detector
- Sensitive to a wide range of fires
- Well suited for environments such as hotel bedrooms
- Unaffected by wind or atmospheric pressure
-

Apollo XP95 Open-Area Sounder & Beacon, Red Body, Red Lens
- Choice of tones on standard device: Apollo, Slow Whoop and DIN.
- Two volume settings 92dB(A) and 100dB(A).
- Synchronisation of 'alert' and 'evacuate' tones.
-

Apollo XP95 Sounder Circuit Controller
- The Sounder Control Unit is used to control the operation of a zone of conventional sounders and report their status to the control panel.
- Allows sounders to be operated continuously or be pulsed; 1 second on, 1 second off
- May be synchronised with loop sounders
-

Apollo XP95 Switch Monitor
- Designed to monitor one or more Single Pole Volt Free Contacts and report the status
- 4 Input States
- Two Visable LED's
- Loop Powered